Loading...
HomeMy WebLinkAbout279958_3_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108132 PROJECT ADDRESS: 3417 S Olive St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/4/2021 INITIAL REVIEW 10/20/2021 EXPIRATION 4/2/2022 RECHECKS: 1.12/14/2021 PROJECT APPLICANT CONTACT PERSON: 2. Basel Almshat 3. TEL: (562)254-1926 FAX: VALUATION: $12,000.00 EMAIL: balmashat@supergreensolutions.com FLOOD ZONE: X-0602320259J Update sheet index on sheet PV-1.0 to include all sheet information. Per sheet PV-6.4, the EcoDesigner report is not for construction. Update this sheet with the final design for construction. Also see item #4 for design requirements. Submit (2) copies of ballast design and anchorage to roof framing by a license professional engineer licensed in the State of California. The design shall comply with 2019 California Building Codeto support minimum wind and seismic force under the most critical load combination. PC2: Per submitted report (page 2) by CBC and plan S-1, (2) seismic attachment to the roof structural is required for the system. Provide engineering design and detail for the attachment. Details shall be part of the drawings and stamped and signed by the licensed engineer. The engineer of record, PVR engineering who is in responsible charge of the building structural design supporting the PV system shall provide a statement on the ballast design stating that he or she has reviewed and approved for loads, location, and suitability for intended use. Provide approval stamp with signature from the engineer or architect of record on the ballast design and anchorage to roof framing. END OF COMMENTS