Loading...
HomeMy WebLinkAbout280072_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108172 PROJECT ADDRESS: 3603 W Garry Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/6/2021 INITIAL REVIEW 10/10/2021 EXPIRATION 4/4/2022 RECHECKS: 1.1/28/2022 PROJECT APPLICANT CONTACT PERSON: 2. Dustin Padua 3. TEL: (949)339-3930 FAX: VALUATION: $100,000.00 EMAIL: dustin.padua@safeworkcm.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS A common area is created along with suite 3603. This common area is shared with all (3) suites and have access to all suites. A separate address may be needed. Prior to the next submission, please contact Planning Division for addressing concern. (Ali Pezeshkpour @ 714-647-5882 or apezeshkpour@santa-ana.org.) All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - OC Sanitation DistrictObtain Building and EMP permits for “3605 W Garry unit”. Submit design and plans to show compliance with fire, life and safety code requirements. Please contact Allissa Zuniga to process for permit application and information. A separate building permit number is required for TI for 3605 unit. Plans for 3605 unit can be combined and submitted together with this package. Note that both 3603 and 3605 W Garry units permit shall be issued together.Sheet A0.1. Provide a statement, incorporated on the first sheet, addressed to the Building Safety Division describing in detail the manufacturing process from material delivery, storage, handling, packaging, and shipping of finish product.Include an equipment list describing use in the process.Clear state the function of each suite which related to cannabis business.PC2: I am not able to find the statement. Please provide it on a conspicuous place on the cover sheet.Sheet A0.1. Show occupancy group of each unit: “3601, 3603 and 3605 W Garry” under project data.Sheet A0.1. Show common area square footage on plan, including lobby, restroom and breakroom square footage which is not belong to any suite.PC2: A common area is created along with suite 3603. This common area is shared with all (3) suites. Prior to the next submission, please contact Planning Division for addressing. (Ali Pezeshkpour @ 714-647-5882 or apezeshkpour@santa-ana.org.)On the cover sheet, show separate square footage for 3603 unit and common area. Do not combine.Provide glass wall design on plan, located in packaging room #109 and distribution office #112. Glass located in the fire-rated assembly shall comply with CBC Section 716.PC2: Glass and glazing shall be in accordance with CBC Chapter 24. Note on the drawings all windows and doors having glazing. Indicate the type and thickness of each light of glazing on the drawings.ACCESSIBILITYBUILDING ACCESSIBILITYProvide accessible drinking fountain details on plan for both high and low fountain. No fewer than two drinking fountains shall be provided. When provided, one drinking fountain shall comply with 11B-602.1 through 11B-602.6, 11B-602.8 and 11B-602.9 and one drinking fountain shall comply with 11B-602.7 and 11B-602.9. §11B-211.2 (See exception)PC2: Details are not provided.All drinking fountains shall either be located completely within alcoves, positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways. The protected area within such a drinking fountain is located shall be 32 inches wide minimum and 18 inches deep minimum, and shall comply with Section 11B-305.7 Maneuvering Clearance. When used, wing walls or barriers shall protect horizontally at least as far as the drinking fountain and to within 6 inches vertically from the floor or ground surface. §11B-602.9PC2: Sheet A2.2. Provide elevation of detail 4/A2.2.Detail 7/A0.5. Revise mounting height for wall-mounted signage. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters. Refer to Figure 11B-703.4.1. (11B-703.4.1).PC2: Dimensions on the detail is not clear. Add note to plan (underline section in this comment) for mounting height requirement.Sheet A2.2. A few details in the keynotes and legends that refer to sheet A0.6 DO NOT EXIST. Provide referenced accessible element details on plan. (e.g. note #251 refer to 5/A0.6)PC2: Details are removed. Provide cross referencing into plan.Sheet A2.2. Details in the keynotes #256-#258 are not cross-referenced.PC2: Still not cross-referenced.Provide detail 3/A2.3. Refer to sheet A2.2 for note #253.PC2: Still not cross-referenced.STRCUTURALProvide a cross section for the glass partition at packaging room #109 and distribution office #112 detailing the support of the top of the partition to the roof or floor above and to the floor below.PC2: Design is not available on either architectural or structural plan.Sheet S2.1. Keynotes #4. Provide connection detail for demising walls (separating tenant units) spanning from finish floor to the roof framing. Detail 16/S3.1 does not apply.PC2: Sheet S2.2. Roof framing plan. Please clarify and revise the design at the new partition wall (full height) located inside the (2) existing skylight opening. Provide connection design and detail to provide top bracing of the wall to support minimum 5 psf lateral live load.Sheet S2.1. Clarify the location where the detail 16/S3.1 applies. Per architectural sheet A5.0, justify the attachment and unbraced length of the diagonal bracing (ceiling height: 9 feet vs top of parapet: 22 feet).PC2: Structural design is not provided on the structural plan. NEW COMMENTS PER REVISED PLANA common area is created along with suite 3603. This common area is shared with all (3) suites and have access to all suites. A separate address may be needed. Prior to the next submission, please contact Planning Division for addressing concern. (Ali Pezeshkpour @ 714-647-5882 or apezeshkpour@santa-ana.org.) Sheet A2.0. Doors located within 1-hour fire-rated demising wall shall have minimum ¾-houor fire rated opening protection. Revise plan to show compliance. This correction was on the check set, but not being pick up.Sheet A6.0. The new full-height 1-hour demising wall is framed into the (2) existing skylights. Review and revise design to provide continue fire separation, and structural connections of the wall at the roof.END OF COMMENTS