HomeMy WebLinkAbout283280_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109152
PROJECT ADDRESS:
1601 E Edinger Ave
PLAN CHECK ENGINEER:
Huang, GaryTEL:714
647-5862
EMAIL:
Ghuang@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/18/2022
INITIAL REVIEW
1/21/2022
EXPIRATION
7/17/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Ryan Bloom
3.
TEL:
(562)254-5212
FAX:
VALUATION: $10,000.00
EMAIL:
rbloom@ocrecycling.com
FLOOD ZONE: X-0602320276J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5862 for an appointment.Please return marked up set of drawings with correctionsDrawings submitted to the Building Division for review shall provide the following information to insure compliance with CBC Section 11B-202.4/Chapter 11B:
- An accessible entrance
- An accessible route to the altered area
- Accessible restrooms
- Accessible telephone (if any)
- Accessible drinking fountains, and
- Parking, signage and alarmsComplete the attached Disable accessibility Document FormThe applicant shall obtain clearances/approvals for the following, prior to building permit issuance:☐Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.☒Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840).☐Public Works Agency approval (647-5039).☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Red marked comments set is available to pick-up at the City Hall☒Additional Review Comment: Sheet SP:A) Identify location of the accessible parking space(s)B) Identify accessible route from an accessible parking space to the accessible building entranceC) Provide an accessible pedestrian gate on the new CMU wall to maintain accessible pathD) Provide accessible gate design and details complying with CBC 11B-404E) Show the width of the pedestrian sidewalkF) Provide consistent background. The background on sheet SP shows pedestrian side walk, but the background on sheet sw and sheet fp does not. Sheet fp-1:A) Provide on plan, structural material notes, i.e. concrete strength, mix ratio, steel reinforcement, CMU block/grout material strength, etcB) Provide detail/calculation for steel metal gate attachment to CMU blockC) Provide on plan for wind and earthquake design data per CBC 1603D) Provide lateral analysis for CMU block wall design. Calculation is incomplete, further review is required. Update/revise CMU fence wall detail based on the revised calculation Sheet fp-2:A) Please clarify if the pole footing embedded in soil calculation is for the signage on sheet NSP? Provide wind load analysis per ASCE 7, Chapter 29. Wind load shall acting at the middle of the sign at 12’-0”. B) Provide calculation show how both earthquake and wind load were derived.C) Provide on plan for structural detail for concrete embedded footing. D) Provide structural design/detail of “Alternate signage” anchorage to CMU fence wall. See sheet NSP for additional comments Sheet nsp:A) Indicate on drawing maximum signage weight on drawing for the cantilever signB) Indicate on drawing maximum signage weight on drawing for the “Alternate” sign. C) Provide calculation and anchorage detail attachment for “Alternate” sign to CMU block wall(End of Comment)