HomeMy WebLinkAbout283760_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109317
PROJECT ADDRESS:
1801 E St Andrew Pl Unit# 200
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
III B, SPK
OCCUPANCY CLASSIFICATION(S):
B, F-1, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
2/2/2022
INITIAL REVIEW
3/16/2022
EXPIRATION
8/1/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Chip Bleeker
3.
TEL:
(949)300-8038
FAX:
VALUATION: $18,500.00
EMAIL:
chip@bleekerbros.com
FLOOD ZONE: X-0602320277J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet A-1.0: Building Information: Please verify number of stories of the existing building. coordinate with information provided on sheet A-2.0 and A-3.0. Sheet A-3.1: Please show/provide (maintain) minimum 3-ft clear around the spray booth unit per Section 2404.3.3.5 CMC. The spray booth is located on the second floor: Floor supporting the spray booth shall be constructed with minimum one-hour fire-resistance rating floor assembly. Walls supporting the one-hour floor assembly shall be rated at equal or greater than the floor assembly. Please revise plan and provide details for floor and wall assembly. Please provide building section to show clearance between top of spray booth unit and ceiling. A 3-ft minimum clear is required. Spray booth Unit – Please provide spray booth shop drawing and specification. Please provide listing number and report for the spray booth. Structural supportPlease provide roof framing plan and details to show support of the roof top mechanical equipment (spray booth exhaust fan and chimney). Provide floor framing plan and details to show support of the spray booth unit, including anchorage. Provide complete structural calculation. Engineer stamp: Please update engineering expiration date. **Please note: Plan was incomplete. Plan review will continue and additional comment may be required at time of resubmittal.