HomeMy WebLinkAbout284000_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109372 PROJECT ADDRESS: 1714 E McFadden Ave Unit# H Bldg# 3 PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/8/2022 INITIAL REVIEW 2/19/2022 EXPIRATION 8/7/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Cesar Romero 3. TEL: (949)302-7821 FAX: VALUATION: $86,000.00 EMAIL: cesar00romero@gmail.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Per building record, revise type of construction to type III-B.Provide a site plan. Submit fully dimensioned plot plan including:Show all property lines of record on the site plan. Location of the tenant space within the building.Accessible parking stalls (CBC 11B-208, 11B-502)Accessible routes within the boundary of the site from public transportation stops, accessible parking and accessible passenger loading zones, and public streets or sidewalks. (CBC 11B-206)Sheet A201. Cross-reference wall type from sheet A670 into floor plan note #4.Sheet A201. Equipment schedule.Provide specification for equipment F through H.EGRESSSheet G0. Revise occupant load factor from 200 to 60 per CBC Table 1004.1. Update calculation on plan. (See red marks).SITE ACCESSIBILITY When alterations or additions are made to existing buildings or facilities, an accessible path of travel to the specific area of alteration or addition shall be provided unless otherwise exempt. (CBC 11B-202.4) Identify all features that will be altered to bring into current compliance with (CBC 11B-202.4) BUILDING ACCESSIBILITYEntrances, exits and paths of travel – entrances, limit threshold = ½” max.; level area 60” in direction of door swing, 48” opposite door swing, 24”(exterior)/18”(interior) jamb clearance; bottom 10” of door to be smooth, uninterrupted surface, etc. (CBC 11B-404.2.5, 11B-404.2.4, Table 11B-404.2.4.1, 11B-404.2.10)Sheet A201. Provide 18”clearance of the latch side at the gate between retail and cashier, measured perpendicular to the face of the door or gate. (CBC 11B-404.2.4.3 & Figure 11B-404.2.4.3 (a))Sheet A650. Detail 5. Clearance around water closet shall be 60” measured perpendicular from side wall and 56” from rear wall. Show dimensions on plan.END OF COMMENTS