HomeMy WebLinkAbout283814_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109327 PROJECT ADDRESS: 1621 S Diamond St PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/8/2022 INITIAL REVIEW 3/10/2022 EXPIRATION 8/7/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Heather Vo 3. TEL: (714)757-1387 FAX: VALUATION: $10,000.00 EMAIL: heathery2kre@gmail.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☒Police Department approval on the corrected/final set of drawings (647-5840). ☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DrawingsSheet T1Add Flood Zone: X in Building Summary.Sheet A2Square note 1 references 3/A3. Please provide detail. New emergency exist windows shall be 5’ minimum height to ensure 24” minimum height clearance. Else specific manufacturer to be provided showing net clear height.Note on plan: Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection.Sheet S1Provide called out detail 12/SN1 on ADU foundation plan.Verify HIP1 Beams between Grid 2 and 3 are to be supported by ridge beam. Current plans show no KP or detail and have HIP beams spanning to 2x8 Ridge beam. Please provide detail. For HIP1 Beam between Grid 1 and 2, see comment in calculations. For new addition to existing house, verify detail 1/SN2 and 2/SN2 called out. If posts are to span to foundation, please provide detail condition showing floor sheathing and rim beam around post.For new addition to existing house, provide new roof rafters on framing plan at new California framing left of Grid 5 and between Grid 5 and 4.Provide blocking and detail for strap at Grid D.Detail 1 & 2 – Provide referenced detail 16 at anchor.CalculationsJustify Cr = 1.15 for all headers and hip/ridge beam calculations.Verify HIP1 designed with cantilever is not supported by BM2. If intended to be free at end, please specify on drawings or add reaction to BM2.(End of Comment)