HomeMy WebLinkAbout282943_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109058 PROJECT ADDRESS: 1810 N Greenwood Ave Unit# 2 PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/10/2022 INITIAL REVIEW 1/18/2022 EXPIRATION 7/9/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Lorraine Ohls 3. TEL: (714)227-7276 FAX: VALUATION: $80,000.00 EMAIL: lorena.ohls@gmail.com FLOOD ZONE: X-0602320163J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.Comments have been provided on drawing and calculation hard copies correlating to all comments below. These may be picked up at Building and Planning department at applicants’ discretion. Documentation: Comment # Comment 1 Structural calculations not provided. Please provide calculations stamped and signed by a licensed Engineer. Drawings: Comment # Sheet Comment 1 G-1 Add Occupancy Classification R-3/U to project information 2 A-1 Add note on sheet “Voluntary ADA compliancy provided by owner. City does not enforce or review any ADA compliancy shown on drawings” 3 Verify window 1 quantity on schedule. 4 Provide new landing dimensions, slopes, and any elevation changes on floor plan at all exit doors. 5 A-2 Show and provide exhaust fan in kitchen. 6 Note on plan: Mechanical, electrical, and plumbing are not part of this plan review and approval. MEP are subject to building field inspection. 7 A-3 Eave projection not allowed where fire separation is less than 2’-0”. Existing eave to be demo’ed and shown on plan on demo plan. 8 A-4 Coordinate new slab thickness with structural. 9 S-1 All final drawings and calculations shall be stamped and signed by a licensed engineer.