HomeMy WebLinkAbout282415_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108903 PROJECT ADDRESS: 901 W Civic Center Dr Unit# 400 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: II A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/15/2021 INITIAL REVIEW 1/12/2022 EXPIRATION 6/13/2022 RECHECKS: 1.2/12/2022 PROJECT APPLICANT CONTACT PERSON: 2. Sean Nourani 3. TEL: (424)365-2070 FAX: VALUATION: $150,000.00 EMAIL: architectseannourani@outlook.com FLOOD ZONE: X-0602320144J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Reference detail 05/A1.1: Please revise detail to show wall mounted sign at 60” above finish grade, and the 80” clear should be measured to the lowest sign provided on the post. 2nd Review Comment: Please clarify detail 05/A1.1 to clearly indicate the 60” minimum height is for the wall mounted sign and 80” minimum height is for the post mounted sign. Sheet A2.3: Fire-rated exit passageway: Please show the beginning of the protected exit passageway. Exit passageway shall be enclosed by fire-rated wall, ceiling, and opening protection (rated doors). Please coordinate and revise plan accordingly. 2nd Review Comment: On sheet A2.3 & A2.4 – Please note “Existing exit passage way to remain” as applicable. Sheet A2.4: Fire-rated exit passageway: Please show the beginning of the protected exit passageway. Exit passageway shall be enclosed by fire-rated wall, ceiling, and opening protection (rated doors). Please coordinate and revise plan accordingly.2nd Review Comment:Please note “Existing exit passage way to remain”.Sheet AD.1: Detail 11/AD.1: Please provide structural support and details for the glass wall. Provide calculation. 2nd Review Comment: Response was incomplete. Please provide the following information – Sheet A4.0: Please provide glass window/panel schedule for panel 9, 10, 11, 12, ect. Provide structural calculation and details for support of the large glass wall panels.