Loading...
HomeMy WebLinkAbout280646_3_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108340 PROJECT ADDRESS: 2116 S Bristol St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/1/2021 INITIAL REVIEW 11/11/2021 EXPIRATION 4/30/2022 RECHECKS: 1.12/24/2021 PROJECT APPLICANT CONTACT PERSON: 2.03/18/2022 Geri Fox 3. TEL: (951)545-4004 FAX: VALUATION: $850,000.00 EMAIL: gfox@permitsfast.com FLOOD ZONE: X-0602320257J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)PLAN CHECK COMMENTS:Provide exit tactile sign detail. For the purpose of Section 1013.4, the term “tactile exit signs” shall mean those required signs that comply with Chapter 11B, section 11B-703.1, 11B-703.2, 11B-703.3 or 11B-703.5.PC2: Incorrect mounting height. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters. Refer to Figure 11B-703.4.1. (11B-703.4.1).PC3: Please correct the wall-mounted tactile exit sign on plan.Sheet A6.0. List the provisions in CBC Section 1010.1.9.8item #11 for the door equipped with a delayed egress lock.PC2: Missing provisions on plan: CBC 1010.9.8.1 item #6.4 and CBC 1010.9.8.1 item #7.PC3: Not resolved. Please add missing CBC requirements in the notes on the architectural plan.Detail1/A4.1. Provide 36” wide detectable warnings around the exterior door landing. Note that detectable warning shall not be encroached into the required door maneuvering clearance or landing space.PC2: detectable warnings shall be around the landing on all edges between door landing and vehicular way.PC3: Not resolved. See redlines on plan.Provide checkout area and jewelry area shall be accessible:Spaces and elements within employee work areas shall only be required to comply with CBC Sections 11B-206.2.8, 11B-403.5, 11B-207.1 and 11B-215.3. (CBC 11B-203.9)The customer side of checkout aisles, sales counters, food service lines, queues and waiting lines shall comply with CBC Sections 11B-227 and 11B-904. (CBC 11B-227.1)PC2: The floor plan (e.g. sheet A1.0) does not indicate the above area is under separate permit. Provide design and details on plan. PC3: The jewelry area is part of this permit (see scope of work and separate permit item on the cover sheet), provide accessible design for this area on plan.END OF COMMENTS** No additional redlines on plan**