HomeMy WebLinkAbout285211_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109706 PROJECT ADDRESS: 609 S Newhope St PLAN CHECK ENGINEER: So, AnsonTEL:714 647-5830 EMAIL: aso@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/9/2022 INITIAL REVIEW 3/13/2022 EXPIRATION 9/5/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Luis Guzman 3. TEL: (714)791-4398 FAX: VALUATION: $12,500.00 EMAIL: sivaaoscar@gmail.com FLOOD ZONE: X-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet A1.0An engineering stamp is not required on the architectural sheets; however, when the engineering stamp is shown, the Engineer On Record shall provide his or her signature at the engineering stamp.Correct the note under Code Compliance. This project is located in city of Santa Ana, not city of Ontario.Correct the note on occupancy under Zoning. This is an apartment building, but a single family residence.Clearly show the area of work on the site plan. Detail 3/S3.0 indicates special inspection is required for post-installed anchor bolts. Please indicate Special Inspection is required on the title sheet.Sheet A2.1Show the vehicle damaged area on the East Elevation.Provide a window schedule. Specify window height, width, type, U-factor, solar heat gain factor,…etc.Is this an egress window? Identify the use of the room adjacent to this replaced window. An egress window is required if this is a bedroom. Provide details per California Residential Code Section R310 if required.Correct the detail referencing number on AA Section.Structural DrawingsProvide Engineer On Record’s signature on all structural drawings.[END]