HomeMy WebLinkAbout285241_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109718
PROJECT ADDRESS:
604 S Harbor Blvd
PLAN CHECK ENGINEER:
So, AnsonTEL:714
647-5830
EMAIL:
aso@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/9/2022
INITIAL REVIEW
3/18/2022
EXPIRATION
9/5/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
David R Gamboa
3.
TEL:
(714)597-5560
FAX:
VALUATION: $60,000.00
EMAIL:
aes.dave67@gmail.com
FLOOD ZONE: X-0602320256J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5830 for an appointment.Sheet T1Since unit 602A and 606 will be deactivated, revise the address to “604 S. Harbor Blvd.” on the title block and all drawings.Verify the occupancy group under Building Information. Is it a business or mercantile occupancy group?On the site plan, the word “Vacant” is shown on unit 604. Are you proposing a “Spec Suite” design? If so, see additional handout for Spec Suite requirements.Structural drawings show new column, footing, and walls. Include all new structural work under Scope of Work.
Sheet A1-EShow a dimension line between the office and the restroom. What is the clearance between the walls?The toilet door-swing location does not match between the floor plan and the detail.What is the fire rating at the demising wall between unit 602 and 604? Show the level of fire rating of the demising wall on the plan.
Sheet A2-RReference structural plans and details at the vehicle-damaged area.Sheet A2-CShow the travel distance with dimension from the most remote location within unit 604 to the exit door.Show the exit signage location, details, and specifications on the plan.At the vehicle-damaged area, provide details for new windows and walls.The toilet door-swing location does not match between the floor plan and the detail.Door schedule A indicates panic bar, but the exterior double-door near the restroom swings inward. It appears to be an error.Sheet S-1Provide structural calculations for the new column and footing.Sheet S-2On detail 6, are the post and hold-down existing or new?There are no shear-walls shown on plans. Delete the Shear Panel Schedule.