HomeMy WebLinkAbout281756_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101108695 -96
PROJECT ADDRESS:
1901 E Alton Ave
PLAN CHECK ENGINEER:
Ahangian, KathyTEL:714
647-5812
EMAIL:
Kahangian@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/8/2021
INITIAL REVIEW
12/30/2021
EXPIRATION
6/6/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Kimberly Kilgour
3.
TEL:
(213)787-0657
FAX:
VALUATION: $500,000.00
EMAIL:
kimberly.kilgour@smithgroup.com
FLOOD ZONE: X-0602320278J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Fire Department approval on the corrected/final sets of drawings ((714)573-6100)
- Public Works Agency approval (647-5039)
- Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by
the Public Works Agency (647-5039)
- Proof of Worker’s Compensation Insurance shall be required at the time of permit issuance Please note on the plan if there is any parking re-slurry besides new accessible parkings. Provide parking data on the site plan showing the total number of parking spaces provided, the number of disabled accessible spaces and the number of van accessible spaces, showing compliance with Table 11B-208.2.Provide complying exiting plan from the buildings to the public sidewalk.Provide number of exits required by CBC Sections 1006.CBC Section 1022.1, Exit continuity. Exits shall be continuous from the point of entry into the exit to the exit discharge.Note on drawing: “Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort.”CBC Section 1010.1.2.1Exit doors shall swing in the direction of exit travel when serving any hazardous area or when serving an occupant load of 50 or more.The City of Santa Ana requires concrete exterior door landings. Revise the drawings to show compliance.( Provide at each side of pedestrian gateOn Curb ramp please show minimum 36 “ wide portion without detectible warning to allow pedestrian travel in the direction of side walk. 11B-705.1.2.2.2. Show location of all pedestrian gates and card readers on the site plan.CBC Section 11B-404.2.7 Note on the drawings: “Maximum effort to operate doors shall not exceed 5 pounds for exterior doors and interior doors, such pull or push effort being applied at right angles to hinged doors and at the center place of sliding or folding doors. Compensating devices or automatic door operators may be utilized to meet the above standards. When fire doors are required, the maximum effort to operate the door may be increased to the minimum allowable by the appropriate administrative authority, not to exceed 15 pounds. Show location of all new light standards, provide height and dimension of the light standards.Provide structural calculations and drawings, stamped and signed by a California licensed architect or registered civil engineer for:
- 8’ high fence
- light standardsProvide complete construction detail for security fence, post spacing ,…