HomeMy WebLinkAbout283526_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109245
PROJECT ADDRESS:
2740 S Bristol St Unit# 200
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/26/2022
INITIAL REVIEW
2/9/2022
EXPIRATION
7/25/2022
RECHECKS:
1.2/28/2022
PROJECT APPLICANT CONTACT PERSON:
2.3/23/2022
John Cha
3.
TEL:
(949)310-7495
FAX:
VALUATION: $75,000.00
EMAIL:
remjohn4@gmail.com
FLOOD ZONE: X-0602320259J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet G02: On the plan, please clearly show an accessible route from the accessible parking stall to the building primary accessible entrance. 3rd Review Comment: Please show an accessible route from the accessible parking stall to the building primary entrance. Accessible route shall be 5% maximum slope, in the direction of travel, and 2% maximum cross-slope. 3rd Review Comment: Please note on plan “Accessible route shall be 5% maximum sloped in the direction of travel, and 2% cross-slope. Sheet A01: Restrooms: Please clearly reference to sheet A02 for the accessibility requirement. 3rd Review Comment: Floor plan – Please clearly cross-reference to detail 1/A02 for accessible restroom plan and detail. Detail 1/A02: Single accommodated restroom 3rd Review Comment: Restroom adjacent to the laundry room, with the door swing inward – Please provide restroom plan with door swing inward and show door shall not encroach more than 12” into the 60” turning circle. Sheet A03: Details provided on sheet A03 appeared inconsistence with the floor plan. Please revise details to show one-hour walls, corridor ceiling, etc. 3rd Review Comment: Wall construction details provided on sheet A03 were incomplete. Please provide construction details to show wall connection at bottom (floor); at ceiling, at brace connection; at braces to structural frame above, etc. Details shall be clearly cross-reference onto the plan and shall be legible.
(End of Comment)