HomeMy WebLinkAbout282876_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109039
PROJECT ADDRESS:
1010 E Santa Clara Ave
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/5/2022
INITIAL REVIEW
2/8/2022
EXPIRATION
7/4/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Mitchell & Maricela O'Sullivan
3.
TEL:
(657)217-9680
FAX:
VALUATION: $60,000.00
EMAIL:
maricelamo2004@yahoo.com
FLOOD ZONE: X-0602320163J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☒Public Works Agency approval (647-5039).
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DrawingsSheet T-1Add all structural sheets to sheet index.Sheet A-1Provide material and details for new landing. Coordinate with structural, sheet S2.11 calls out pre-cast concrete stairs by others. If deferred, add deferred list to cover sheet.Verify building dimensions, some look to have incorrect lengths. (e.g. +/- 164’-0” from edge of building to CL of window)Provide wall demo length at door on Demo plan.Sheet U-1Provide carbon monoxide alarm outside new bedroom.Note on plan: Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection.Sheet D-1Detail 6 – Reference detail on plan where occurs, or omit.Detail 6 – Coordinate stringer size with structural, no stairs are shown on structural sheets.Sheet C0.1Final structural sheets shall be signed.Sheet S1.01Detail 1 – Provide rebar epoxy information and ICC #.Sheet S2.11Verify (E) lateral force resisting system along line with new expanded door opening. Justify (E) system is adequate with new opening.(E) Ceiling Joist line not legible. Verify detail 7/S1.22 at new strap is correct reference or revise.CalculationsStructural calculation package shall be signed by licensed Engineer.(End of Comment)