HomeMy WebLinkAbout280072_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101108172 PROJECT ADDRESS: 3603 W Garry Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/6/2021 INITIAL REVIEW 10/10/2021 EXPIRATION 4/4/2022 RECHECKS: 1.1/28/2022 PROJECT APPLICANT CONTACT PERSON: 2.3/25/2022 Dustin Padua 3. TEL: (949)339-3930 FAX: VALUATION: $100,000.00 EMAIL: dustin.padua@safeworkcm.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - OC Sanitation DistrictSheet A1.0. The scope of work shows the common area is cancelled. Please update “Proposed site plan” to update proposed tenant area location and entrance.Delete common area and note #131. Update the note #110 at the back door for exit only.Identify the location of the accessible parking serving suite 3605 and location of the entrance to suite 3605. The accessible parking shall be located on the shortest accessible route from parking to an entrance complying with Section 11B-206.4.Please note that the building entrance for suite 3605 will need to be relocated since it is no longer shared common area with 3603 on the proposed design. Please remember to update the design on the 3605 tenant improvement(permit #101108402).Sheet A1.1. Delete new opening between suite 3601 and suite 3603. Delete note #108.Detail 7/A0.5. Incorrect measurement. Revise mounting height for wall-mounted signage. Tactile characters on signs shall be located 48 inches minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60 inches maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters. Refer to Figure 11B-703.4.1. (11B-703.4.1).END OF COMMENTS