HomeMy WebLinkAbout283507_2_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109236 PROJECT ADDRESS: 1349 N Santiago St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/26/2022 INITIAL REVIEW 1/30/2022 EXPIRATION 7/25/2022 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Frank Wright 3. TEL: (310)750-8939 FAX: VALUATION:$40,000.00 EMAIL: fwright082@gmail.com FLOOD ZONE:X-0602320163J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.Include address and telephone number of the responsible designer, and date of signing of drawings.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.PC2: Obtain electrical permit. On the building plan review, add note to sheet A-501: “for reference only”.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Additional Building permitand plan review is required. This building permit cannot be issued unless the following permit are obtained:Sheet A-401. The alteration of the door #2 shall be added to this permit and listed in the scope of work on the cover sheet.New large building openings.PC2: Per revised plan, please add alteration of all exterior doors and adding new 48”x96” awning into this permit. Update permit valuation.PC2: Please DO NOT USE drop-off carts for submitting the new plans. An appointment is needed to modify scope of work prior to building recheck the new plans. Please schedule an appointment with Planning and Building permit counter staff (Allissa Zuniga @ 714-647-5854) at the counter to add this gate into building permit at the time of submitting the recheck for corrections.Sheet A-001. Clarify occupancy group on the cover sheet in accordance with 2019 CBC chapter 3. The S occupancy shall be further classified either S1 or S2 per storage material.Sheet A-001. Revise square footage of the tenant improvement area to match the building dimensions: from 2477 sf. to 2447 sf. (39’11”x61’) to match site plan dimensions.Sheet A-001. Provide complete description of the scope of work on plan.PC2: Refer to comment #7 to include all scope of work on the cover sheet.Sheet A-001. List site improvement permit number on the cover sheet and the site plan note.PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-101. Provide site improvement plan building permit number. PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-101. Show total number of parking spaces, van accessible parking spaces and standard accessible parking spaces on plan.PC2: show number of van accessible parking spaces and standard accessible parking spaces on plan.Provide demolition plan to clearly show any alterations of interior partitions and structural exterior walls. Provide structural design and connection details for the new awnings.Sheet A401. Some keynotes refer to structural drawings for more information. However, the structural design is not available. Please coordinate with the structural engineer to provide required information on plan. (e.g. keynote #4)PC2: Provide structural calculation, design and details for (4) large openings made on both east side and west side. Justify structural integrity to support vertical and horizontal forces.Sheet A-201. The as-built plan shows no partitions and no accessible restrooms. If this is true, add note on plan to clarify.Sheet A-401. The alteration of the door #2 shall be added to this permit and listed in the scope of work on the cover sheet.Sheet A-401. The proposed floor plan shows no partitions. If this is true, add note on plan to clarify.Sheet A-401. Clarify if there is any accessible restroom located within the building. Sheet A-401. Add note to plan to clarify whether this building is air-conditioned. Note that alteration of doors and windows shall be added to the permit scope of work. Alteration of windows or glazed door shall comply with 2019 CEC.Sheet A-401. Provide ICC number for Neo-lith sintered stone ventilated façade.PC2: The ICC ESR-number is not available (E.g. refer to the keynote #7 on sheet A-401).NEW COMMENTSSheet A-001. Revise sheet index to show correct architectural and structural drawings’ information.Sheet A-201. Cross-reference floor plan key notes #7 through #10 into the floor plan.EGRESSPending.Provide exterior door landing on plan with dimensions. Show design method to comply with accessibility and not to be encroached by park cars and landscape.Provide design on the enlarged site plan to clarify.Note the following on the plans: “The means of egress, including the exit discharge, will be illuminated to a level of not less than one foot-candle at the walking surface at all times the building space served by the means of egress is occupied”.Note on the plans: “Exit signs shall be internally or externally illuminated at all times. Externally illuminated exit signs shall be connected to an emergency power system (batteries, unit equipment or an on-site generator) that will automatically illuminate the exit signs for a duration of not less than 90 minutes in case of primary power loss.”ACCESSIBILITYPlease show accessible routes within the boundary of the site from public transportation stops, accessible parking and accessible passenger loading zones, and public streets or sidewalks to the proposed building accessible entrance.PC2: Not shown.When alterations or additions are made to existing buildings or facilities, an accessible path of travel to the specific area of alteration or addition shall be provided unless otherwise exempt. (CBC 11B-202.4)Along the exterior accessible path of travel, identify curb ramps, detectable warnings, accessible route width and required maneuvering space at the exterior door landing on plan. Identify all features with details that will be altered to bring into current compliance with (CBC 11B-202.4)Entrances, exits and paths of travel – entrances, limit threshold = ½” max.; level area 60” in direction of door swing, 48” opposite door swing, 24”(exterior)/18”(interior) jamb clearance; bottom 10” of door to be smooth, uninterrupted surface, etc. (CBC 11B-404.2.5, 11B-404.2.4, Table 11B-404.2.4.1, 11B-404.2.10)PC2. Response to item 1 through 4. Plans are still lack of required information by Code and still not clear. Please revise and provide enlarged site plan, design and details to provide design complying with Code.Fill out the disabled access compliance documentation form. Clarify in the form and on plan if the existing accessible path of travel fully or partially complies with 2019 CBC and show if any proposed design, detail and location of improvement in compliance with accessibility requirements along the accessible path of travel in accordance with CBC Section 11B-202. Note: Return the filled form at the next plan check submittal.PC2: The form is not submitted.Sheet A-401. Clarify if there is any accessible restroom located within the building. If not, show on the site plan and provide accessible route where the accessible restroom serves this building.PC2: show on the site plan and provide accessible route where the accessible restroom serves this building.STRUCTURAL-IncompletePlans and the scope of work does not match. New design and, building permit may be required. New corrections may apply.PC2: Provide structural calculation, design and details for (4) large openings made on both east side and west side. Justify structural integrity to support vertical and horizontal forces.Multiple large openings are made into the exterior walls which is not under this permit. Please apply building permit and approved prior to this permit. If it is under separate permit, show permit number on plan to and clearly indicate any not-in-contract item. (CBC and ASCE 7-16)PC2: The revised architectural plan clarifies that the (4) openings, (2) on the west side and (2) on the east side are under this permit. Provide structural calculation, design and details for (4) large openings made on both east side and west side. Justify structural integrity to support vertical and horizontal forces and bracing between A-frame columns.Please submit (2) copies of the structural calculation. The cover page of the structural calculation shall be stamped, dated, and signed by the engineer of record.PC2: Only (1) copy of calculation is submitted.Provide specification and ICC number for the CFS studs.Provide connection design for the new Neo-lith sintered stone ventilated façade attached to the new framing. Provide attachment details and calculation to justify the design.PC2: Per revised architectural plan, the exterior covering is changed to Moto-extrusions façade system. Please update structural calculation.Provide structural design, calculation, framing and connection details for the new Awning. (Refer to architectural plans and detail 9/D-400).Sheet S-0.10. Revise seismic parameters on plan to match calculation.Sheet SD-1.0 and SD-2.0. Cross-reference all details to the framing and foundation plan. Delete details which do not apply to this project. New corrections may apply after next review.Detail 1 and 2/SD1.0:Provide wind calculation for components and cladding to design the 8 feet tall parapet. Specify the bracing member specification and space. Provide design to support the most critical out-of-plane lateral force.Provide design and detail to support the lateral in-plane force on the new CFS wall.Provide connection design and detail at the bottom of the metal stud to transfer the design load to the building frame and to the foundation.Design and detail the connection of CFS kicker to L-Plate. Design and specify the CFS studs on plan for both parapet wall and furred walls. Call out specification, spacing and attachment on plan.Specify L-Plate.Clarify air gap between CFS studs and CFS stud to A-frame on detail 1/SD1.0 and 2/SD1.0 to be consistent. Show dimensions of the air gap on plan. Update structural sheet number to match structural sheet index shown on sheet S-0.10. A few sheets are not match. Please update.END OF COMMENTS