PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109240
PROJECT ADDRESS:
1357 N Santiago St
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B, S-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/26/2022
INITIAL REVIEW
2/4/2022
EXPIRATION
7/25/2022
RECHECKS:
1.06/23/2022
PROJECT APPLICANT CONTACT PERSON:
2.
Frank Wright
3.
TEL:
(310)750-8939
FAX:
VALUATION:$45,000.00
EMAIL:
fwright082@gmail.com
FLOOD ZONE:X-0602320163J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed.
Pick up plan (check set) for additional comments marked on the drawing.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.Include address and telephone number of the responsible designer, and date of signing of drawings.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet A-001. Clarify type of construction on plan. The structural design shows wood framed exterior wall may not meet type IIIB construction.PC2: Please revise type of construction to type VB per submitted plans.Sheet A-001. Clarify occupancy group on the cover sheet in accordance with 2019 CBC chapter 3. The S occupancy shall be classified either S1 or S2 per storage material. In addition, the occupancy group shall be consistent thought the entire document (e.g. sheet A-401 floor plan shows B and S2). Revise plan to clarify.PC2: Please revise type of construction to B and S2.Sheet A-001. List site improvement permit number on the cover sheet and the site plan note.PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-101. Provide site improvement plan building permit number. PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-101. Show total number of parking spaces, van accessible parking spaces and standard accessible parking spaces on plan.PC2: show number of van accessible parking spaces and standard accessible parking spaces on plan.Sheet A-101. Add note to the site plan that no structure or roof covering between buildings (Building #4-#9).Sheet A-101. Coordinate with architectural and structural drawings to list all submitted sheets on the sheet index.PC2: Per sheet index, please submit sheet A-801 and D-600. Revise structural sheet index to be consistent with structural drawings submitted.Sheet A-301 through A-601. Provide Interior improvement building permit number on plan.PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-401. Cross-reference missing details into plan.Sheet A-401. Provide ICC number for sintered stone ventilated façade on plan and provide a copy of the report, submitted for review.PC2: The ICC ESR-number is not available (E.g. refer to the keynote #7 on sheet A-401).STRUCTURALThe cover page of the structural calculation shall be signed by the engineer who stamps the calculation. (2) Copies of calculation are required. PC2: Only (1) copy of calculation is submitted.END OF COMMENTS.