HomeMy WebLinkAbout283513_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109241
PROJECT ADDRESS:
1359 N Santiago St
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/26/2022
INITIAL REVIEW
2/5/2022
EXPIRATION
7/25/2022
RECHECKS:
1.06/23/2022
PROJECT APPLICANT CONTACT PERSON:
2.
Frank Wright
3.
TEL:
(310)750-8939
FAX:
VALUATION: $45,000.00
EMAIL:
fwright082@gmail.com
FLOOD ZONE: X-0602320163J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed.Pick up plan (check set) for additional comments marked on the drawing.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Sheet A-001. Clarify type of construction on plan (VB?). The structural design shows wood framed exterior wall may not meet type IIIB construction.In addition, the fire-rating requirements on the parapet shall also comply with Table 601 and table 602 based on the location of the imaginary lot line. If the imaginary lot line is placed in the middle between building 1, building 2 and this building, the fire separation distance (FSD) is between 10 and 30 feet. Per Table 602, 1-hour rated parapet is required for type IIIB or 0-hour rated parapet for type VB.PC2: The parapet construction does not meet type IIIB construction. Please revise type of construction to type VB per submitted plans.Sheet A-001. Clarify occupancy group on the cover sheet in accordance with 2019 CBC chapter 3. The S occupancy shall be classified either S1 or S2 per storage material. Per floor plan, I do not see where the Storage occupancy applies. Please assign proper occupancy for this building based on the use.Sheet A-001. Please add (4) new awnings into the scope of work description.PC2: On plan, revise scope of work from adding (3) to add (4) new awnings into the scope of work.Sheet A-001. List site improvement permit number on the cover sheet and the site plan note.PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-101. Provide site improvement plan building permit number. PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-101. Show total number of parking spaces, van accessible parking spaces and standard accessible parking spaces on plan.PC2: show number of van accessible parking spaces and standard accessible parking spaces on plan.Sheet A-101. Add note to the site plan that no structure or roof covering between buildings (Building #4-#9).Sheet A-101. Coordinate with architectural and structural drawings to list all submitted sheets on the sheet index.PC2: Per sheet index, please submit sheet A-801 and D-600. In addition, revise structural sheet index to be consistent with structural drawings submitted.Sheet A-301 through A-601. Provide Interior improvement building permit number on plan.PC2: The provided numbers: 1049-7564 / 1049-7563/ 1049-7562) are not building permit numbers. Please clarify.Sheet A-401. Provide ICC number for sintered stone ventilated façade on plan and provide a copy of the report, submitted for review.PC2: The ICC ESR-number is not available (E.g. refer to the keynote #7 on sheet A-401).Sheet A-501. The new roofing is not in the scope of work. Please revise plan and notes to remove it (or provide ICC number on plan and add it to the scope of work)STRUCTURALThe cover page of the structural calculation shall be signed by the engineer who stamps the calculation. (2) Copies of calculation are required. PC2: Only (1) copy of calculation is submitted.END OF COMMENTS