Loading...
HomeMy WebLinkAbout283144_2_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109112 PROJECT ADDRESS: 1010 N Tustin Ave PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: Type IIA OCCUPANCY CLASSIFICATION(S): A3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/13/2022 INITIAL REVIEW 2/24/2022 EXPIRATION 7/12/2022 RECHECKS: 1.07/20/2022 PROJECT APPLICANT CONTACT PERSON: 2. Kenny Sommer 3. TEL: (714)693-2277 FAX: VALUATION:$500,000.00 EMAIL: KSommer@oed-inc.com FLOOD ZONE:X-0602320164J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840). - Public Works Agency approval (647-5039).PLAN CHECK COMMENTS:Provide a site plan. Submit fully dimensioned plot plan including: (Aerial photo is not an accepted site plan)Show all property lines of record on the site plan. Location of all structures on the site.North arrowAccessible parking stalls (CBC 11B-208, 11B-502)Provide Building Info on the cover sheet T1: Specify construction type (s) (CBC Ch.6). Clarify either building is Type IIA or Type IIB? (Per building permit #10156500, the building is classified as Type II F.R. which is equivalent to Type IIA per current code)Please justify the existing building lateral support system is adequate to support additional lateral force from the equipment units.Please show page number where the justification can be found.Please do not submit partial structural calculation as “updated” or “only response to correction comment”. The original structural calculation shall be updated to match the structural design. At next submission, provide two complete structural calculation (assemble all applicable pages), stamped and signed by the licensed design professional for final approval.END OF COMMENTS