HomeMy WebLinkAbout282481_2_Corrections.docxPLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101108927
PROJECT ADDRESS:
3100 S Susan St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
F-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/16/2021
INITIAL REVIEW
2/2/2022
EXPIRATION
6/14/2022
RECHECKS:
1.7/5/2022
PROJECT APPLICANT CONTACT PERSON:
2.
Michael Howie
3.
TEL:
(323)982-7619
FAX:
VALUATION: $110,000.00
EMAIL:
michael.howie@coffman.com
FLOOD ZONE: X-0602320258J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
Cover Sheet: Please provide/specify building area, type of construction and occupancy group(s) on the plan.
2nd Review Comment: Sheet S0.1 – Please revise occupancy groups (B, S-1) and construction type (III-B) to match with architectural plan sheet A-0.
Due to the alteration/improvement (structural improvement) of the existing building, accessibility requirement shall be complied with Section 11B-202.
On the plan, please show/provide “path of travel” information in compliance with Section 11B-202.4.
Show accessible parking space(s) and accessible route from the accessible parking to the building primary entrance.
Show accessible primary entrance
Accessible restrooms
Drinking fountains, if provided
Etc.
2nd Review Comment: Architectural site plan and accessibility information were provided. Please provide the following requirement information.
Keynote 3, 4, and 6 – For clarity, please revise note to limit cross-slope of 1:48 (2%) and eliminate all other slope dimension (such as 3.5%, 4.3%, 2.6%, etc.).
Please show concrete curb ramp with detectable warning on the north side of the building where giving access from the north accessible parking stalls. Curb ramp shall comply with Section 11B-406.
On the plan, please clearly identify/show location of the Van accessible parking stall.
The single parking stall located on the south side of the property – Please revise plan to provide/relocate the accessible access aisle to the driver side so that the passenger would not require to travel behind the parked vehicle located on the right side of the drive aisle.
Please provide information for the restrooms. Existing restrooms shall be made accessible to persons with disabilities. Please provide restroom plans and details to show compliance with Chapter 11B, Division 6.
Sheet A-0, Note #48 – Please revise note to specify “THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED”.
Please incorporate the architectural and structural plans (sheets) into a set of plans.
(End of Comment)