HomeMy WebLinkAbout289938_1_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101111152
PROJECT ADDRESS:
1821 N Grand Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
A-3, B, E
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
7/13/2022
INITIAL REVIEW
7/20/2022
EXPIRATION
1/9/2023
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Mario Hernandez
3.
TEL:
(949)774-2909
FAX:
VALUATION:
EMAIL:
marioh@studiow-architects.com
FLOOD ZONE: X-0602320163J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTSThe applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.Add note to the plan:” Washing machines and clothes dryer’s operable parts must comply with Section 11B-309 Operable Parts.”11B-611.3A clear floor or ground space complying with Section 11B-305 positioned for parallel approach shall be provided. The clear floor or ground space shall be centered on the appliance.Show clear floor spaces on plan.11B-611.2.Stacked dryer on the top of the cloth washer does not comply with the following reach range:Top loading machines shall have the door to the laundry compartment located 36 inches maximum above the finish floor. Front loading machines shall have the bottom of the opening to the laundry compartment located 15 inches minim and 36 inches maximum above the finish floor. 11B-611.4END OF COMMENTS