HomeMy WebLinkAbout290051_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111189 PROJECT ADDRESS: 1220 1/2 W Second St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/14/2022 INITIAL REVIEW 11/16/2022 EXPIRATION 1/10/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Rubens Calderon 3. TEL: (714)803-4250 FAX: VALUATION: $15,000.00 EMAIL: rubenscalderon@gmail.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Plan was not legible. Please provide legible plans (see sheet A-2, S-1, D-1, etc.). Sheet A-1: Please provide construction detail for one-hour fire-rated wall at exterior walls locate less than 5-ft from the property line. Detail shall be clearly cross-reference onto the walls where required. (see redline on A-1) SheetA-1: Bathroom window is not an emergency egress – Please remove “emergency egress” note for bathroom window. Specify tempered glass for the bathroom window. Title 24 sheet T1: Title 24 compliance form, Section H – Please revise to specify U-factor = 0.30 and SHGC = 0.23. Plan showed tankless water heater – Please revise Section L reflect with floor plan (currently Title 24 showing as 50 gallon tank water heater). Please review printout plans to make sure plans are legible before submitting to the City. (End Comment)