HomeMy WebLinkAbout291091_1_Corrections.docxPLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111510 PROJECT ADDRESS: 3511 W Sunflower Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B, SPK OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/2/2022 INITIAL REVIEW 8/26/2022 EXPIRATION 1/29/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Joseph Hernandez 3. TEL: (626)710-8306 FAX: VALUATION: $15,000.00 EMAIL: projectdox@dcexpediting.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A001: The valuation of the project as $15,000.00 appears understated. Please provide justification for the project valuation. Sheet A100: The new compressor showed on the north side of the building: The referenced permit PC# 101110100 was not valid. The scope of PC# 101110100 was only for the rotation unit located inside the building with associated roof top equipment. Please coordinate and revise plan accordingly. Per scope of work on sheet A001, please show location of new generator and specify size of generator. Sheet A101: No structural information was provided for the proposed equipment pads and equipment anchorages. Provide structural information for the equipment pads. Provide structural plans, details, and calculation. Provide a typical detail for the underground conduit trenching. Sheet S201: Please coordinate with the architectural plans to provide structural design and details for the equipment pads. Provide structural calculation and details. Provide structural calculation and details for the equipment anchorage. (End of Comment)