HomeMy WebLinkAbout282481_4_Corrections.docxPLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101108927
PROJECT ADDRESS:
3100 S Susan St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B, SPK
OCCUPANCY CLASSIFICATION(S):
F-2
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
12/16/2021
INITIAL REVIEW
2/2/2022
EXPIRATION
6/14/2022
RECHECKS:
1.7/5/2022
PROJECT APPLICANT CONTACT PERSON:
2.7/28/2022
Michael Howie
3.
TEL:
(323)982-7619
FAX:
VALUATION: $110,000.00
EMAIL:
michael.howie@coffman.com
FLOOD ZONE: X-0602320258J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
-Public Works Agency approval (647-5039).
Due to the alteration/improvement (structural improvement) of the existing building, accessibility requirement shall be complied with Section 11B-202.
On the plan, please show/provide “path of travel” information in compliance with Section 11B-202.4.
Show accessible parking space(s) and accessible route from the accessible parking to the building primary entrance.
Show accessible primary entrance
Accessible restrooms
Drinking fountains, if provided
Etc.
2nd Review Comment: Architectural site plan and accessibility information were provided. Please provide the following requirement information.
3rd Review Comment: Response was incomplete. Please provide the following –
Sheet A-0: Scope of work – Please include the statement for structural seismic upgrade.
Sheet ST-1: Access route from the right side (north side) was not part of the accessible upgrade – Please omit the accessible route designation (arrows) from the north side of the parking stalls.
Sheet ST-1: Please provide an enlarged site plan to show the demolition limit for the new accessible walkway per hardship form.
Sheet ST-1: Please provide an enlarged site plan to show the proposed layout of parking stalls and accessible route.
Sheet ST-1: Truncated dome is not required at the parking access aisle.
Sheet ST-1: Please revise plan to provide Van accessible parking on the right side of the driveway (closer to the building) and rearrange the access aisle for the parking on the left side of the driveway to the driver side so that it does not require the person to travel behind the adjacent parked vehicle.
Sheet ST-1: Plan showed there is a drain V-ditch in the middle of the driveway – Please provide detail to show the V-ditch is not exceed 5% slope, measured in the direction of travel and 2% cross-slope.
(End of Comment)