HomeMy WebLinkAbout283144_3_Corrections.docxSPC
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101109112
PROJECT ADDRESS:
1010 N Tustin Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
Type IIA
OCCUPANCY CLASSIFICATION(S):
A3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/13/2022
INITIAL REVIEW
2/24/2022
EXPIRATION
7/12/2022
RECHECKS:
1.07/20/2022
PROJECT APPLICANT CONTACT PERSON:
2.
Kenny Sommer
3.
TEL:
(714)693-2277
FAX:
VALUATION:$500,000.00
EMAIL:
KSommer@oed-inc.com
FLOOD ZONE:X-0602320164J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840).
- Public Works Agency approval (647-5039).PLAN CHECK COMMENTS:Provide a site plan. Submit fully dimensioned plot plan including: (Aerial photo is not an accepted site plan)Show all property lines of record on the site plan. Location of all structures on the site.North arrowAccessible parking stalls (CBC 11B-208, 11B-502)Provide Building Info on the cover sheet T1: Specify construction type (s) (CBC Ch.6). Clarify either building is Type IIA or Type IIB? (Per building permit #10156500, the building is classified as Type II F.R. which is equivalent to Type IIA per current code)Please justify the existing building lateral support system is adequate to support additional lateral force from the equipment units.Please show page number where the justification can be found.Please do not submit partial structural calculation as “updated” or “only response to correction comment”. The original structural calculation shall be updated to match the structural design. At next submission, provide two complete structural calculation (assemble all applicable pages), stamped and signed by the licensed design professional for final approval.END OF COMMENTS