HomeMy WebLinkAbout291765_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111691 PROJECT ADDRESS: 1442 S Ritchey St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B, SPK OCCUPANCY CLASSIFICATION(S): B, F-2, S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 8/18/2022 INITIAL REVIEW 9/19/2022 EXPIRATION 2/14/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Carlos Lopez 3. TEL: (909)919-0067 FAX: VALUATION: $30,000.00 EMAIL: charliegone1999@yahoo.com FLOOD ZONE: X-0602320277J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A-1: Scope of work: Reminder – Please transfer the handwritten statement of removing of existing demising wall between 1446 & 1442 to the electronic file prior to reprinting. Applicable Code: Please include the 2019 California Electrical Code, 2019 California Mechanical Code, 2019 California Plumbing Code, 2019 California Energy Code, and 2019 California Green Building Code. Scope of Work: Per City permit record, the existing building is 12,000 square foot. Please coordinate and revise square footage of the existing building. Site plan: The google aerial map is not acceptable to use as a site plan. Please provide an architectural site plan to show property lines, parking stalls, all buildings located on the same lot. On the plan, please clearly show/provide an accessible route from the public sidewalk to the building primary entrance. On the plan, please provide/show location of accessible parking stall(s) and an accessible route from the accessible parking stall to the building primary entrance. Accessible route shall be 5% maximum slope, measured in the direction of travel, 2% maximum cross-slope and 48” wide minimum. Provide/show curb ramp and detectable warning where required. Sheet A-2: Please provide a separate existing floor plan showing existing floor plan with the existing demising wall that has been removed. Egress shall be continuous and unobstructed to the public street. Please show existing fences and mean of egress gates (exit gates). Please provide an egress plan showing occupant load calculation and travel distance. Restrooms: Restrooms shall be made accessible to persons with disabilities. Please provide restroom plans and information to show compliance with Section 11B, Division 6 of the 2019 California Building Code. Structural Review Comment:Existing demising wall to be removed: Please verify if wall was a structural (bearing wall). If it was a structural wall, provide structural plans, details and structural calculations to replace the structural wall that has been removed. (End of Comment)