HomeMy WebLinkAbout283509_3_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109238 PROJECT ADDRESS: 1353 N Santiago St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): S-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/26/2022 INITIAL REVIEW 2/4/2022 EXPIRATION 7/25/2022 RECHECKS: 1.06/22/2022 PROJECT APPLICANT CONTACT PERSON: 2.09/02/2022 Frank Wright 3. TEL: (310)750-8939 FAX: VALUATION:$40,000.00 EMAIL: fwright082@gmail.com FLOOD ZONE:X-0602320163J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTSARCHITECTURALSheet A-001. Revise sheet index to show correct structural drawings’ information.Provide missing sheet A-405 as indicated in the sheet index.Please provide egress plan:Show total occupant load of the building.Show maximum travel distance on plan, measured from the most remote point within a story to the entrance to an exit along the natural and unobstructed path of egress travel (right-angle method), shall not exceed the distances given in Table 1017.2 and common path of travel.Show maximum common path of travel.Show maximum travel distance.Delete illuminated signs from sheet A-501 (see redmarks) which are not located at the exit doors.Provide exterior door landing on plan with dimensions. Show design method to comply with accessibility and not to be encroached by park cars and landscape.Note the following on the plans: “The means of egress, including the exit discharge, will be illuminated to a level of not less than one foot-candle at the walking surface at all times the building space served by the means of egress is occupied”.Note on the plans: “Exit signs shall be internally or externally illuminated at all times. Externally illuminated exit signs shall be connected to an emergency power system (batteries, unit equipment or an on-site generator) that will automatically illuminate the exit signs for a duration of not less than 90 minutes in case of primary power loss.”Sheet A-401. Provide accessible curb ramp design at the edge of sidewalk and pedestrian crossing.Sheet A-401. Delete detectable warning which located on the sidewalk. Refer to plan check #101109232 for balance of corrections. STRUCTURALRefer to plan check #101109232 for balance of corrections.Update structural drawing number on the drawing title to match structural sheet index on sheet S-0.10.END OF COMMENTS