HomeMy WebLinkAbout290708_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111410 PROJECT ADDRESS: 1907 N Main St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): M, B, S1 or S2? PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/27/2022 INITIAL REVIEW 7/30/2022 EXPIRATION 1/23/2023 RECHECKS: 1.9/8/2022 PROJECT APPLICANT CONTACT PERSON: 2. Joseph Rodriguez 3. TEL: (714)914-8896 FAX: VALUATION: $5,000.00 EMAIL: rodriguezjoseph577@gmail.com FLOOD ZONE: X-0602320163J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Public Works Agency approval (647-5039)Sheet T-1. In addition to M occupancy, specify the CBC occupancy group classification(s) of the tenant space on the plans per CBC chapter 3 including office area (B) and storage area (S1 or S2?).Sheet A-2.2. Relocate the tactile exit route sign from the new partition by the door E to the latch side of the exterior door by the door D.Per submitted disabled access compliance documentation form, identify the items to be made accessible for path of travel upgrades. add note to the scope of work that: Scope of accessible path of travel upgrades:Items to be made accessible: Installation of 2 grab bars and signage.The existing non-compliant van accessible parking space is not part of the accessible path of travel upgrades per 2019 CBC 11B-202.4 item #8.Detail 4. Revise location of the 30”x48” clear floor space not encroached by the shower posts.Detail 5/ ADA-1. Revise wall mounted restroom sign to comply with technical requirements for raised characters (CBC 11B-703.2), braille (CBC 11B-703.3), visual characters (CBC 11B-703.5), and requirements for installation height and location (CBC 11B-703.4). No pictogram is required. The following signs illustrate acceptable examples for designation sign text:Provide detail for installing toilet rear grab bar. The rear grab bar shall be 36 inches long minimum and extend from the centerline of the water closet 12 inches minimum on one side and 24 inches minimum on the other side. §11B-604.5.2END OF COMMENTS