HomeMy WebLinkAbout290783_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111430 PROJECT ADDRESS: 1710 S Main St PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): B, M PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/28/2022 INITIAL REVIEW 8/17/2022 EXPIRATION 1/24/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Alvin Santos 3. TEL: (323)465-7066 FAX: VALUATION: $20,000.00 EMAIL: alvin@rsharch.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840)Sheet A1-01: The Note (statement) provided at the bottom right of the page was insufficient. Due the improvement inside of the building (T.I), accessible path of travel complying with Section 11B-202.4 shall be provided. The architect of record shall verify and provide accessibility requirement on the plan. Plan must be legible. Sheet A2-01: Floor plan showed/indicated new new (N) produce stands/shelves, replace (R) shelves, and etc. – For clarity, please revise plan to removed indication of new (N) or replace (R) if they are existing and not part of this permit application.On the plan, please show location of restrooms and show restrooms complying with Chapter 11B, Division 6. Sheet A3-01: Please provide elevation of new guard railing.Guardrails shall have guy rail locate not more than 27” above the walking surface.Gate detail 2: Please revise detail to show bottom of gate locate 10 inches minimum and 27” maximum above finish floor.(End of Comment)