HomeMy WebLinkAbout290693_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111403 PROJECT ADDRESS: 1241 S Grand Ave PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/27/2022 INITIAL REVIEW 8/10/2022 EXPIRATION 1/23/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Tyson Habee 3. TEL: (619)517-1509 FAX: VALUATION: $175,000.00 EMAIL: thagee@elementsarch.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. 5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☒Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☒Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DrawingsSheet A2.1Provide accessible route from new accessible parking stall to existing building entrance. Specify entrance on plan intended for route. Ensure adequate ADA detectable warning on building side adjacent to vehicle path. Provide material specs for all new material. (conc, steel, etc…)Specify new aisle stripping width at all new striping shown on plan.Provide truncated dome at new guard shack area that has accessible route.Specify full extent of new striping on plan where cutoff.If new gate next to building is intended to be used for ADA route, provide gate details specifying all ADA requirements per CBC. Sheet A3.1Specify all new foundation locations on plans.Sheet A8.1Detail 4 – Verify detail reference 12/A4.1. Typical all details, various detail references do not match. Detail 1 – Verify if foundation is square or round.Detail 3 – Provide weld information.Detail 7 – Verify 6” and 4’-2” dimension shown.Detail 9 – Provide minimum reinforcing in foundation and verify if square or round foundation.Detail 12 – Provide weld information.(End of Comment)