HomeMy WebLinkAbout292473_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101111918 PROJECT ADDRESS: 1427 S Van Ness Ave PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 9/7/2022 INITIAL REVIEW 10/7/2022 EXPIRATION 3/6/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Ernesto Estrada 3. TEL: (714)501-9975 FAX: (714)542-3800 VALUATION: $30,000.00 EMAIL: estrada.ee@gmail.com FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. Sheet A1: Taped or glued information on plans were insufficient. Please provide permanent information on the plan. Sheet A1, Floor plan: Existing bedroom with new expansion – Provide emergency escape window complying with current code. The escape opening shall have a minimum net clear opening of 5.7 sq. ft. with 24" minimum net clear height and 20" minimum net clear width. Escape window shall have a finished sill height not more than 44" above the floor. At grade-floor is allowed to have escape opening of 5.0 sq. ft. (R310.1) Sheet S1: Framing Plan – Provide detail at new beam to show beam supporting existing roof frames. Detail shall be clearly cross-referenced onto the plan. New beam RBM: Please specify beam size. Structural design may be required. Since portion of existing exterior wall to be removed, please provide new braced wall along the existing exterior wall line (adjacent to the new addition). Provide hold-down with capacity at least 800-lb at each end of braced wall panel where there are no return panel at the end of braced wall panel. (Figure R602.10.7) Provide drag strut (straps) at new RBM and existing wall. Provide strap between new wall and existing wall. Sheet S1: Footing detail F1A: Please revise detail to show minimum 12” clear between grade (under floor grade) and bottom of floor girder beam. Concrete strength: Please revise detail F1 to specify minimum concrete strength of 3000 psi. Reminder: Plan must be legible. (End of Comment)