Loading...
HomeMy WebLinkAbout285391_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101109770 PROJECT ADDRESS: 1212 S Bristol St Unit# 17 PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B, F-1, M, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 3/14/2022 INITIAL REVIEW 5/11/2022 EXPIRATION 9/10/2022 RECHECKS: 1.08/04/2022 PROJECT APPLICANT CONTACT PERSON: 2.08/30/2022 Lawrence Wright 3. TEL: (714)426-2952 FAX: VALUATION: $370,000.00 EMAIL: lawrence@yngarchitects.com FLOOD ZONE: X-0602320257J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Please return marked up set of drawings with corrections.CBC Sections A106.1 and A106.3.4.1, All drawings and supporting documents shall be prepared, stamped and signed by a California licensed architect or registered civil engineer.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100) - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039) - County of Orange Health Department approval on the corrected/final set of drawings ((714)433-6000)PLAN CHECK COMMENTS:Identify existing fire walls on plan. This building is classified as type VB with no fire sprinklered. Fire walls may be utilized to separate the building not to exceed the allowable floor area. (NS=9000 sf for B occupancy)PC3: Provide building allowable area analysis per CBC 508 to prove the building is within the allowable floor area based on the proposed occupancies. If fire wall occurs, show fire-rating and location on the site plan.Remove and enclose the door between office and adjacent units. Revise plan to provide detail of enclosing the door opening.PC3: Detail 1/A2.6 is not clear. Please clarify which fire assembly (fire wall vs fire barrier vs fire partition) the door is located and provide correct assembly detail per CBC Ch 7. END OF COMMENTS