HomeMy WebLinkAbout293472_2_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101112248 PROJECT ADDRESS: 2621 3/4 S Birch St Unit# WCC01 PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/17/2022 INITIAL REVIEW 10/23/2022 EXPIRATION 4/15/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Samantha Bauman 3. TEL: (951)384-8430 FAX: VALUATION:$50,000.00 EMAIL: samantha@tangent.systems FLOOD ZONE:X-0602320278J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. 5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DrawingsSheet T-1Please verify in scope of work where 6’-0” high CMU wall is to occur on plan. Else remove from scope of work.Address in title block should be 2621 3/4 as noted in application. Typical all sheets. Sheet S-1Verify anchor embedment with calculations.Verify new concrete pad thickness. 6” foundation noted on generator slab, 8” shown in section, 9” used in anchorage design.CalculationsPlease verify provided Simpson Strong-Bolt 2 designed embedment with drawings. Revise to match as needed. Please verify concrete thickness for new pad, see drawing comments. Simpson anchor design shall be designed with Seismic design applied for governing seismic loads. Please revise.Verify interaction check done for Simpson anchor, justify no shear in interaction check.(End of Comment)