HomeMy WebLinkAbout285315_2_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104109744
PROJECT ADDRESS:
2526 S Birch St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
II B, SPK
OCCUPANCY CLASSIFICATION(S):
B, F-1, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/10/2022
INITIAL REVIEW
4/28/2022
EXPIRATION
9/6/2022
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Sosi Bardakjian
3.
TEL:
(714)496-3095
FAX:
VALUATION: $100,000.00
EMAIL:
sosi@gnkauto.com
FLOOD ZONE: X-0602320278J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Submittal was incomplete. Plan review will continue at time of resubmittal and additional comments may be required. Plans shall be prepared and stamped, signed and dated by a California registered civil engineer and/or licensed architect. Site plan: Please show property lines and all buildings located on the same lot. Please specify construction shall comply with the 2019 CBC, CMC, CEC, CPC, California Energy Code, California Green Building Code. Please provide the following building information on the cover sheet: Occupancy groups Type of ConstructionFloor area for each occupancy, on each floor, etc. Sprinkler Provide site plan to show accessible parking stalls and provide an accessible route from the accessible parking stalls to the building primary entrance. Accessible route shall be 5% sloped maximum, measured in the direction of travel, 2% cross-slope, and 48” clear width. Otherwise, accessible ramp is required. Please provide demo floor plan to clearly show location of all walls to be removed/demo. Structural walls shall be remained. Please revise plans for the correct job address 2526 S. Birch Street. Per permit record, the existing building was a type II-B construction. Therefore, combustible (wood) construction is not allowed. Please revise construction details for the proposed restroom. Sheet A-1: Restroom Accessible water closet – Please show water closet located at 17”-18” from the adjacent wall, measured to the centerline of the water closet. Show dimensions on the plan.Side grab bar – Please show grab bar extended minimum 24” beyond the water closet, measured from the front edge of the water closet. Show dimensions on the plan. Please provide accessible signage for accessible restrooms, including tactile signs.