HomeMy WebLinkAbout294014_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101112409 PROJECT ADDRESS: 1337 S Parton St PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 10/18/2022 INITIAL REVIEW 11/29/2022 EXPIRATION 4/16/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. George Valencia 3. TEL: (949)254-6454 FAX: VALUATION: $5,000.00 EMAIL: gvalencia1@sbcglobal.net FLOOD ZONE: X-0602320276J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. 5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DocumentationVerify if calculations have been completed for new patio cover. Members on structural sheets show member ID’s that look to reference calculations (e.g. RB-4), please provide calculations.Structural sheets shall be stamped and signed by licensed engineer referenced in title block. DrawingsSheet A-1Provide a project description with a complete and detailed scope of work on the cover sheet of the plans.Verify if demo’ing existing porch cover. If existing porch cover is to be demolished, please specify in scope of work.Revise code reference, no code references should reference city of LA.Sheet S-2Details provided on sheet are illegible, please enlarge.Provide new trellis framing sizes and details, including beam sizes, post sizes, connections, foundation, etc. Please coordinate with detail 36/D-2 referenced on plans, detail shows 2x2 over RR over beam over post.Provide new roof sheathing information on plans or reference where information is located.Provide 2x6 RR spacing on plan.Provide detail for projection from end of framing at Roof Rake side.Provide support at interior end of new 4x10 ceiling beam. (End of Comment)