Loading...
HomeMy WebLinkAbout295437_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 103112879 PROJECT ADDRESS: 501 W Dyer Rd PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B, F-1, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 11/28/2022 INITIAL REVIEW 12/14/2022 EXPIRATION 5/27/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Paul Krause 3. TEL: (714)641-5005 FAX: VALUATION: $7,000.00 EMAIL: paulk@aircleaningtechnology.com FLOOD ZONE: X-0602320278J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. (No additional plan check comments are marked on the drawings). Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process.Cover sheet. Under the “summary/analysis” area, please update the following on plan:Allowable area for B occupancy: 9000 sf.Allowable area for S-1 occupancy: 9000 sf.Allowable area for F-1 occupancy: 8500 sf.Allowable building height: 40 feet.Type of construction: VB.Cover sheet. Under the “description of work” area, indicate this permit number and provide description of the scope of work for this revision. Identify with delta number for this revision only.The permit application shows alteration to the rooftop units. However, the submitted plans do not have any information shown on this revision. Please clarify with the applicant and provide relevant design on the drawings. Plans and structural calculation may be required:Please provide detailed response in writing to this item clarifying if any rooftop equipment (RTU) is added or altered.For adding or altering RTUs, architectural roof plan, equipment specification, structural design including roof framing plan, equipment and screen (if provided) framing, anchorage design, calculation and details are required. Further plan review is required and correction comments may be issued.Door #120. Recessed doors maneuvering clearances for forward approach shall be provided when any obstruction within 18” of the latch side at an interior doorway measured perpendicular to the face of the door. (CBC 11B-404.2.4.3 & Figure 11B-404.2.4.3 (a))Provide illuminated exit signs on the egress side of the door #120 and door #121.Provide tactile exit signs on the egress side of the door #120 and door #121. Each exit access door from an interior room or area to a corridor or hallway, which is required to have a visual exit sign, shall be identified by a tactile exit sign with the words “EXIT ROUTE.”END OF COMMENTS