HomeMy WebLinkAbout290096_4_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102111205 PROJECT ADDRESS: 1111 W Santa Ana Blvd PLAN CHECK ENGINEER: Ahangian, KathyTEL:714 647-5812 EMAIL: Kahangian@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V A, SPK OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/15/2022 INITIAL REVIEW 8/16/2022 EXPIRATION 1/11/2023 RECHECKS: 1. 9/21/22 PROJECT APPLICANT CONTACT PERSON: 2. Jeff Weber 3. TEL: (949)254-0135 FAX: VALUATION: $100,000.00 EMAIL: jeffweber1@msn.com FLOOD ZONE: X-0602320257J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5812 for an appointment. Please see corrections on submitted plans. Red marked set must be returned with revised plans. Plans resubmitted without the red markup set may result in delayed review time and additional plancheck fees. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Public Works Agency approval (647-5039). - Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. Provide building information on plans:OK 9/21/22 - Occupancy type: R2 - Construction type: Type V-A - Fire sprinklered: Yes / No Please provide all exit stairways and show if the balconies are exit balcony or private balcony. OK 9/21/22Carbon monoxide alarms combined with smoke alarms shall comply with both sections R314 and section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms.OK9/21/22Provide details of the deck/balcony and specify method of waterproofing. List ICC approval number for decking material. Show two percent minimum slope. Pending 9/21/22 please provide on this drawings, since each permit is an independent permit.For plywood floor diaphragm specify thickness, grade, T&G edges, panel span rating, nailing schedule and panel layout pattern. (CBC 2305, T2305.2.3, 2306.3, T2306.3.1, and T2306.3.2)Pending 9/21/22 Calculation shows 3/4 “ plywood , please revise floor sheathing on the drawings accordingly.Provide structural calculations and drawings, stamped and signed by a California licensed architect or registered Civil Engineer for:Ok 9/21/22 - Guard(s). All wood framing members that rest on concrete or masonry exterior foundation walls and are less than 8” to the exposed ground shall be pressure treated or naturally durable to decay. Ok 9/21/22Live load for balconies and decks shall be per table 1607.A.1, please revise calculation accordingly. Ok 9/21/22Please clarify if floor joists are being replaced, if they are , provide complete framing detail. Ok 9/21/22On detail 1/SD1, show dimension of the balcony and floor joists span. 9/21/22The 4x10 beam, 16’ span, exceeds the allowable span for the grade.Pending 9/21/22 Calculation on sheet B3, shows the beam’s section detail is 5”x 9.5” , but detail A-A on sheet SD2, doesn’t match. Please show 2 x 10 sistered to 4x10 on the drawings with detail to match calculation.Provide spacing for the guardrail post. Ok 9/21/22 Show all structure members are I-hr fire resistance rating , since the building is type VA. Per Table 601.