Loading...
HomeMy WebLinkAbout295684_1_Corrections.docxSPC PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101112950 PROJECT ADDRESS: 830 3/4 S Main St Unit# WCC01 PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: N/A OCCUPANCY CLASSIFICATION(S): N/A PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/2/2022 INITIAL REVIEW 12/11/2022 EXPIRATION 5/31/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Stella Shih 3. TEL: (602)527-3592 FAX: VALUATION:$50,000.00 EMAIL: Stella.shih@rlsusa.com FLOOD ZONE:X-0602320276J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. 5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☐Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☐Police Department approval on the corrected/final set of drawings (647-5840). ☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DrawingsSheet A-8Detail 1 – Verify where new ground mounted detail occurs.Detail 2 – Provide currently applicable ICC # for proposed Hilti anchors in new cable tray attachment.Detail 2- Provide minimum anchor spacing dimension between top and bottom anchor for new Hilti anchors.Sheet BT-1Detail 2 – Specify assumed existing concrete slab thickness.Detail 2 – Proposed anchorage for cabinet does not match calculations, please coordinate with calculations and revise as needed,CalculationsPlease specify if steel angles or unistrut braces shown in Antenna Anchorage sheets are new and intended for scope. It is not clear whether these are to be installed new or are existing as they cannot be located in drawing set. Typical all Sectors. (End of Comment)