HomeMy WebLinkAbout297202_2_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101113468
PROJECT ADDRESS:
1901 W Moore Ave
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3, U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
1/12/2023
INITIAL REVIEW
1/22/2023
EXPIRATION
7/11/2023
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Hans Christian Hansen
3.
TEL:
(714)573-0073
FAX:
(714)573-0688
VALUATION: $75,000.00
EMAIL:
hchansen@msn.com
FLOOD ZONE: X-0602320259J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.
5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY):
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☒Public Works Agency approval (647-5039).
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DrawingsSheet 1
Provide the following design data on the first sheet (R106.1.1)
☒Floor area per occupancy group, including the existing structure(s)Note on plan: Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection.Sheet 2Verify North arrow with Site Plan.Sheet 3Verify North arrow with Site Plan.Provide lateral loading and coordinate design with Truss mfr at Truss on gable end, plan east wall. Detail specifies lateral loading but deferred Truss submittal does not specify any lateral loading used in design for Truss A1. Provide detail for attic access location and dimensions spanning through new truss bottom chords. Coordinate attic access layout with Sheet 2.Sheet 4Provide ceiling height at new Trusses on sections or plans. CalculationsDeferred Truss Submittal – Trusses shall be designed per 2022 CBC, all code references shall reference latest code.Coordinate Truss A1 with engineer for required lateral loading.Hansen Hokoma Calculations – Lateral analysis references 2019 CBC, all code references shall reference latest code.(End of Comment)