Loading...
HomeMy WebLinkAbout289697_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 103111092 PROJECT ADDRESS: 5110 Westminster Ave Unit# M PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 7/6/2022 INITIAL REVIEW 7/17/2022 EXPIRATION 1/2/2023 RECHECKS: 1.9/6/2022 PROJECT APPLICANT CONTACT PERSON: 2.2/7/2023 Anthony D Chau 3. TEL: (714)768-3092 FAX: VALUATION: $30,000.00 EMAIL: ar.dchau@gmail.com FLOOD ZONE: A-0602320143J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)**PLAN WAS NOT REVISED OR THE RESPONSES WERE INCOMPLETE. A MEETING BETWEEN THE DESIGNER AND THE PLAN CHECK ENGINEER IS RECOMMENDED. PLEASE CONTACT THE PLAN CHECK ENGINEER, TUNG LE, FOR MEETING.Sheet A-0: Reminder:Final plans shall be signed and dated by the designer. Apply to all sheets. On the plan, please show/provide an accessible path of travel from the public sidewalk to the building accessible primary entrance. 2nd Review Comment: Response was incomplete. Accessible route shall not cross from an adjacent property (lot). The accessible route shall be independent from the adjacent building. 3rd Review Comment: There is a change in elevation between the existing walkway and public sidewalk. Please provide detail to show ramp. Ramp with slope exceeding 5% shall comply with Section 11B-405. 4th Review Comment: response was incomplete. Details provided did not reflect with the site condition. Please clearly show on the site plan, bottom and top landing, slope, handrails, handrail extension, etc. Details must be specific. Please show an accessible route from the accessible parking stall to the building entrance. 2nd Review Comment: Response was incomplete. Accessible parking stall shall be located on its own parcel. Please revise plan to provide accessible parking stall and curb ramp to be located on the 5110 Westminster Ave lot. 3rd Review Comment: Response was incomplete. Please revise plan to show van parking stall with minimum 8-ft access aisle located on the passenger side. 4th Review Comment: Please provide accessible parking space on its own parcel. Accessible parking must comply with 11B-502. Accessible parking access aisle shall be located on an accessible route. On the plan, please provide detail of concrete curb and detectable warning. Details shall be clearly cross-referenced onto the plan. 2nd Review Comment: Please comply. 3rd Review Comment: Curb ramps are required between the building walkway and parking area - Please revise plan to show curb ramps and provide details to show curb ramp in compliance with Section 11B-406. 4th Review Comment: Accessible parking shall be located on an accessible route. Please show concrete curb, curb ramp, and detectable warning. Provide curb ramp detail to show compliance with 11B-406. On the plan, please provide details for accessible parking stall and signage. Details shall be clearly cross-referenced onto the plan. 2nd Review Comment: Details provided shall be clearly cross-referenced onto the plan. (If applicable) Accessible upgrade may limit to 20 percent of the adjusted construction cost of alterations. (11B-202.4, Exception 8). Please contact plan checker for the Accessible upgrade summary form. (End of Comment)