Loading...
HomeMy WebLinkAbout296335_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101113159 PROJECT ADDRESS: 4528 W Posey St PLAN CHECK ENGINEER: Lo, JonathanTEL:714 647-5822 EMAIL: Jlo@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/14/2022 INITIAL REVIEW 1/4/2023 EXPIRATION 6/12/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. David Nguyen 3. TEL: (510)650-5499 FAX: VALUATION: $180,000.00 EMAIL: httr.3g@gmail.com FLOOD ZONE: X-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2019 California Residential Code (CRC); 2019 California Building Code (CBC); CMC = 2019 California Mechanical Code; CPC = 2019 California Plumbing Code; CEC = 2019 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment. 1. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY): ☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. ☒Public Works Agency approval (647-5039). ☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700). ☒Police Department approval on the corrected/final set of drawings (647-5840). ☒School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work. ☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance. ☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. These may be picked up at Building and Planning department at applicants’ discretion.DocumentationProvided Grading Permit Exemption list shall be included in drawing set on full size page.DrawingsSheet A1.0Scope of work notes 2 new ADU’s, please verify. Structural sheets in Sheet Index does not match provided, please revise. Sheet A2.0Revise ADU address on Site Plan to match correct address.Sheet A5.0Provide new landing at bedroom door dimensions.Provide ridge height for low roof on North Elevation.Sheet SN-1Geotechnical information does not match report provided, please revise.Sheet S-1Verify foundation symbol found in Bed 3 with no foundation.Sheet SD-1Detail 5 – Ensure adequate concrete edge distance provided for Simpson base. Detail 10 & 14 – Vent is not permitted through fire rated system, remove and revise vent requirements as needed.CalculationsSheet 7 – Verify shearwall along Grid C height used in calculations, SW height found to be higher on elevations.(End of Comment)