HomeMy WebLinkAbout298270_1_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 103113822 PROJECT ADDRESS: 1714 E McFadden Ave Unit# A Bldg# 3 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): A-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 2/9/2023 INITIAL REVIEW 2/15/2023 EXPIRATION 8/8/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Gilberto Saucedo 3. TEL: (714)710-2745 FAX: VALUATION: $8,500.00 EMAIL: arturo.sau@hotmail.com FLOOD ZONE: X-0602320276J APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)Sheet A-0: General Note – Please update notes to reflect and reference to the 2022 code edition. Applicable Code – Please update Codes to the 2022 Code edition. Occupancy group: Please revise occupancy group to ‘A-2’ for restaurant use. Please specify the building suite area (in square feet). Scope of work: Please include the new works of the T-bar ceiling per inspection report. Site plan: Please provide a site plan (plot plan) to show all property lines, all building located on the same lot, street, accessible route, accessible parking stalls, north arrow, etc.On the plan, please clearly show an accessible route from the public sidewalk to the building primary accessible entrance. (11B-402)On the plan, please show location of accessible parking stall(s) and accessible route from the accessible parking stall to the building entrance. Accessible parking shall comply with 11B-502.On the plan, please show existing concrete curb, curb ramp, and truncated dome, where occurred. Provide details and clearly cross-reference detail onto the plan. Sheet A-1: On the plan, please clearly show where new works for T-bar ceiling are occurred, per inspection report. Sheet A-2: Please specify new works for the T-bar ceiling, per inspection report. New service area: Please show clear distance (access) at the service area. Exit door 2 and 1: Doors’ hardware shall be equipped with panic hardware. Please specify/provide panic hardware at exit door 1 and 2. Existing Restrooms shall be accessible to persons with disability. Please provide/update restrooms complying with Chapter 11B, Division 6. Provide restroom plan plans with required dimensions and accessible features. Accessible seats: At least 5% of the dining spaces (seats) must be accessible. Please show additional accessible seats / dining spaces. ***PLANS ARE INCOMPLETE. PLAN REVIEW WILL CONTINUE AT TIME OF RESUBMITTAL AND ADDITIONAL COMMENTS ARE REQUIRED.