HomeMy WebLinkAbout295910_2_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101113033 PROJECT ADDRESS: 2115 N Broadway PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V A, SPK OCCUPANCY CLASSIFICATION(S): B PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/7/2022 INITIAL REVIEW 12/16/2022 EXPIRATION 6/5/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Jessica Smarker 3. TEL: (805)444-8677 FAX: VALUATION: $2,706,225.00 EMAIL: jsmarker@hhendy.com FLOOD ZONE: X-0602320163J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made.Please return marked up set of drawings with corrections.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Police Department approval on the corrected/final set of drawings (647-5840) - Public Works Agency approval (647-5039)MEANS OF EGRESSSheet IA-C2. At the stairway by the open office (206), provide a tactile sign comply with section 1013.4 with the words “EXIT STAIR DOWN”.Note the following on the plans: “The means of egress, including the exit discharge, will be illuminated to a level of not less than one foot-candle at the walking surface at all times the building space served by the means of egress is occupied”.Note on the plans: “Exit signs shall be internally or externally illuminated at all times. Externally illuminated exit signs shall be connected to an emergency power system (batteries, unit equipment or an on-site generator) that will automatically illuminate the exit signs for a duration of not less than 90 minutes in case of primary power loss.”ACCESSIBILITYSheet 1A-9.2, IA-9.3. Accessible water closet compartment door. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side an interior doorway, measured perpendicular to the face of the door or gate. §11B-404.2.4.3Sheet IA-9.5. Provide restroom door signage for each sex comply with the following:Men’s toilet and bathing facilities shall be identified by an equilateral triangle, ¼ inch thick with edges 12 inches long and a vertex pointing upward. The triangle symbol shall contrast with the door, either light on a dark background or dark on a light background. §11B-703.7.2.6.1Women’s toilet and bathing facilities shall be identified by a circle, ¼ inch thick and 12 inches in diameter. The circle symbol shall contrast with the door, either light on a dark background or dark on a light background. §11B-703.7.2.6.2Sheet IA-1.2. Door C203. Maneuvering clearances for forward approach shall be provided when any obstruction within 18 inches of the latch side an interior doorway, measured perpendicular to the face of the door or gate. §11B-404.2.4.3END OF COMMENTS