Loading...
HomeMy WebLinkAbout296954_2_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 102113388 PROJECT ADDRESS: 4812 W McFadden Ave Unit# 77 PLAN CHECK ENGINEER: Le, TungTEL:714 647-5896 EMAIL: Tle10@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-2 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 1/5/2023 INITIAL REVIEW 2/1/2023 EXPIRATION 7/4/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Claudio Cendejas 3. TEL: (323)833-3685 FAX: VALUATION: $5,000.00 EMAIL: klacengroup@gmail.com FLOOD ZONE: A-0602320256J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. Sheet A1.1: Please revise applicable codes to 2022 code edition. Detail D3/S1.1: Please revise detail to show distance between lag screws and end of post/beam, relatively. For clarity, please revise note to specify ½” diameter lag screw. Check with structural calculation. Two (2) lag screws – Please provide detail to show screw pattern at point of attachment. Show edge distance. Engineering stamp expiration date has been expired – please update expiration date. Structural calculation: Please update structural calculation to the 2022 CBC and applicable Design Standards. Please update engineering stamp expiration date. Calculation showed 7” long lag screw – Please check depth of wood members for the length of screw; please reduce length so that it would not stick out of the post. Coordinate and revise detail D3/S1.1. (End of comment)