HomeMy WebLinkAbout291812_3_Corrections.docxTENANT IMPROVEMENT
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
104111707-08
PROJECT ADDRESS:
1523 / 1525 E First St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
B, S-1
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
8/22/2022
INITIAL REVIEW
9/26/2022
EXPIRATION
8/22/2023
RECHECKS:
1.12/15/22
PROJECT APPLICANT CONTACT PERSON:
2.2/12/23
Giep Van Le
3.
TEL:
(323)537-5874
FAX:
VALUATION: $52,000.00
EMAIL:
legiep49@gmail.com
FLOOD ZONE: X-0602320276J
APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 2corrected sets of plans.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans
should be submitted to expedite the process.
- Police Department approval on the corrected/final set of drawings (647-5840)
- Public Works Agency approval (647-5039)Building 1523: Provide an accessible path of travel from the public side walk to the building primary entrance. Provide accessible ramp. Provide details and clearly cross-referenced detail onto the plan. 2nd Review Comment:Sheet A.3.1 – New accessible ramp – Intermediate and bottom landings – Provide minimum 6-ft landing in the direction of downward travel. Please show/provide 12” handrail extension on top landing, on both sides. 3rd Review Comment: Revised ramp on sheet A.3.2 –Handrails at the intermediate landings – Please revise plan to show handrails extensions on both sides of ramp (see marked plan for clearity)Building 1525: Existing vehicle repair lifts: Existing vehicle lifts installed without building permit – Please provide structural calculation and details for the vehicle lifts. Plan review will continued at time of resubmittal. 2nd Review Comment: Engineering was not provided. Please provide structural calculation, plan and details for the vehicle lifts. 3rd Review Comment: Calculation provided was incomplete. Please design base connection for the overturning forces (at worse case, where the lift is loaded with the maximum loads at the highest point). Enlarged footing and grade beam may be required