Loading...
HomeMy WebLinkAbout295619_4_Corrections.docxTENANT IMPROVEMENT PLAN CHECK COMMENTS COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101112924 PROJECT ADDRESS: 2803 S Yale St PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: III B OCCUPANCY CLASSIFICATION(S): B, S-1 PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 12/1/2022 INITIAL REVIEW 12/20/2022 EXPIRATION 5/30/2023 RECHECKS: 1.1/27/2023 PROJECT APPLICANT CONTACT PERSON: 2.2/9/2023 Daisy Estrada 3.3/14/2023 TEL: (714)422-5893 FAX: VALUATION: $14,500.00 EMAIL: admin@warehousepermits.com FLOOD ZONE: X-0602320258J APPLICABLE CODE: 2019 CALIFORNIA BUILDING CODE (CBC) WITH CITY OF SANTA ANA AMENDMENTS All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance: - Planning Division approval on the corrected/final set of drawings (647-5804.) Previously approved plans should be submitted to expedite the process. - Fire Department approval on the corrected/final sets of drawings ((714)573-6100)PLAN CHECK COMMENTS:Additional plan check fee may be applied hourly to next review. Starting at the 4th plan review cycle. (this review is the 3rd review cycle)PC4: 1 hour extra plan check hour is added for this review.Plans are revised and become very unclear. On the cover sheet, please indicate type of the racks and length of the racks for the scope of this permit. According to plan, it appears solid-pile type racks are NOT within the scope. Please clarify on the drawings.PC4: Not responded. Provide response in writing to this item AND clarify on the new plans.Per revised floor plan on sheet 2, type soild-pile racks appear NOT within the scope since the first submittal. Please add note on plan under the profile of those racks as:“Not in the scope.”PC4: Not responded. Provide response in writing to this item AND clarify on the new plans.Detail 1/SED1. Show vertical clearance at the attached point between the bottom of the diagonal bracing and beam. Refer to calculation page 10, it shows 3” clearance. Please call out on the detail and show the measuring points of the clearance.Provide anchor bolt calculation for type B racks to design 0.5” diameter x 3.25” embedmentA.B..Per revised floor plan on sheet 2, provide enlarged plan to clearly identify type D and type E racks. The texts on the submitted floor plan are too small to read.Refer to the revised floor plan on sheet 2. The minimum aisle width between racks/shelves shall be 44 inches minimum. Revise horizontal clearance between rack D and rack E.PC4: Revise detail 1 on sheet 3 to show 44” minimum clear aisle width. 3’-7” will not work.Sheet SED 2. Revise the height of the beams in type C elevations to match structural calculation (e.g. page 16) and plan (e.g. sheet 2).Detail 4/SED2. Provide 2.75” minimum height of the double rivet beam on the plan to match calculation. (e.g. page 22). Plan shows 2 11/16” high.Provide complete structural calculation pagesfor framing and anchorage for type D and Type E shelves in addition to a single page of summary.PC4: Full analysis is not found in the new calculation. On the next submittal, please indicate page number where the calculation is added.**There is no additional comments marked on the plans or the structural calculations.END OF COMMENTS