HomeMy WebLinkAbout299942_1_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101114366
PROJECT ADDRESS:
2415 N Hesperian St
PLAN CHECK ENGINEER:
Le, TungTEL:714
647-5896
EMAIL:
Tle10@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
U
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/22/2023
INITIAL REVIEW
5/8/2023
EXPIRATION
9/18/2023
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
David Blausey
3.
TEL:
(714)920-7375
FAX:
VALUATION: $6,000.00
EMAIL:
dhblausey@gmail.com
FLOOD ZONE: AE-0602320144J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit 3corrected sets of plans.
The applicant shall obtain clearances/approvals for the following, prior to building permit issuance:
-Planning Division approval on the corrected/final set of drawings (647-5804). Previously
approved plans should be submitted to expedite the process.
Reminder: Please transfer the Designer contact information (handwritten information) onto the electronic file prior to printing.
Sheet A-01: Please provide the following information on the first sheet
Scope of work
Occupancy group (U / R-3)
Type of construction (V-B)
Applicable Codes (2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code)
Sheet A-04: Structural information provided on the architectural plans shall be consistence with the structural plans. Please coordinate and revise plan accordingly.
Sheet GN: Design loads – Please provide additional loads for the future installation of the roof mounted photovoltaic. Revise structural calculation as necessary.
Structural calculation was misplaced. Please provide two sets of structural calculation for final review and approval. Reminder: Calculations shall be stamped, signed and dated by the engineer of record.
Detail 3, 5, & 16 on sheet SD1: For clarity, please specify bolts/fasteners number and sizes.
(End of Comment)