HomeMy WebLinkAbout301775_1_Corrections.docxSPC
PLAN CHECK COMMENTS
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101114971
PROJECT ADDRESS:
1601 E Chestnut Ave
PLAN CHECK ENGINEER:
Lee, WayneTEL:714
647-5848
EMAIL:
wlee@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
N/A
OCCUPANCY CLASSIFICATION(S):
N/A
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
5/5/2023
INITIAL REVIEW
5/6/2023
EXPIRATION
11/1/2023
RECHECKS:
1.
PROJECT APPLICANT CONTACT PERSON:
2.
Luis Aguilar
3.
TEL:
(714)651-8148
FAX:
VALUATION:$50,000.00
EMAIL:
luis@evidac.com
FLOOD ZONE:X-0602320276J
APPLICABLE CODE: 2022 CALIFORNIA BUILDING CODE (CBC) WITH
CITY OF SANTA ANA AMENDMENTS
All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.This review does not include mechanical, plumbing, fire sprinkler system, or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, fire sprinkler systems, and electrical work. Call 647-5800 for information.The applicant shall obtain clearances/approvals for the following prior to building permit issuance:
- Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans
should be submitted to expedite the process.
- Public Works Agency approval (647-5039).PLAN CHECK COMMENTSACCESSIBILITY REVIEW COMMENTSRevise the plans and parking summary to provide a minimum of (1) van accessible, and(1) standard accessible EV spaces. (Table 11B-228.3.2.1)Show locations of all EV spaces and accessible routes on the site plan. Compliant EV spaces shall be located on an accessible route to an accessible building entrance. (11B-206.4 & 11B-812.5).Show the proposed finished surface slopes and cross-slopes of all EV spaces, access aisles, and accessible routes. Access aisles shall be level with the EV space served, and slopes/cross-slopes shall not exceed 1:48. (11B-302)Provide building sections and dimension the actual vertical clearances along the full length of the vehicle spaces, access aisles and vehicular routes serving the EVCS. A minimum vertical clearance of 98 inches shall be maintained under all vertical obstructions, including cable management systems. (11B-812.4)A0-03, A0-04. Detail 11. Fully dimension all EV spaces on the plans. The minimum dimensions shall be: (11B-812.6)144 inches by 216 inches long for van accessible EV spaces;108 inches by 216 inches long for standard accessible EV spaces;A0-04. Detail 11. The color of all striping and markings shall not be the blue color used for identification of accessible parkingspaces per 11B-502.3.3.(11B-812.7)SIGNAGEDetail and provide identification signage as follows: (11B-812.8)Identification with an ISA(International Symbol of Accessibility) and signs identifying van accessible spaces are not required where a total of four or fewer EV spaces are provided;Five to twenty-five total EV spaces are provided:One van accessible EV space shall be identified by ISA signage;Accessible signage is not required at the standard accessible EV spaces.Identification signs shall be reflectorized with a minimum area of 70 square inches. (11B-812.8.6)The identification sign shall be visible from the EV space it serves.Signs identifying van accessible EV spaces shall contain the words “van accessible.”Identification signs shall be permanently posted either immediately adjacent to the vehicle space or within the projected vehicle space width at the front end of the vehicle space. (11B-812.8.7)Mounting height of identification signs shall be60 inches minimum above the finish floor or ground surface measured to the bottom of the sign; or,80 inches minimum above the finish floor or ground surface measured to the bottom of the sign, when the sign projects over an access aisle or other circulation path.Dimension the height above the clear ground space to all operable parts and controls. All operable parts and control shall be 15 to 48 inches above the clear ground space for both forward and side approaches. (11B-308)STRUCTURAL REVIEW COMMENTSProvide calculation to design and justify anchor bolts shown in detail 1/A0-04 and 5/A-0-04.END OF COMMENTS