HomeMy WebLinkAbout299830_3_Corrections.docxRESIDENTIAL PLAN CHECK
COMMENTS
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
PLAN CHECK NO:
101114331
PROJECT ADDRESS:
101 S Cooper St
PLAN CHECK ENGINEER:
Lo, JonathanTEL:714
647-5822
EMAIL:
Jlo@santa-ana.orgFAX:714
647-5897
TYPE OF CONSTRUCTION:
V B
OCCUPANCY CLASSIFICATION(S):
R-3
PLAN CHECK DATES:
REMARKS/RECHECK ITEMS:
APPLICATION
3/20/2023
INITIAL REVIEW
5/3/2023
EXPIRATION
9/16/2023
RECHECKS:
1.6/5/2023
PROJECT APPLICANT CONTACT PERSON:
2.
David Hung Le
3.
TEL:
(714)868-2499
FAX:
VALUATION: $40,000.00
EMAIL:
brightark@gmail.com
FLOOD ZONE: A-0602320252J
Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed. If you feel that an item is not applicable to your project, note “N/A” and discuss the reason with the plan checker.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. Resubmit marked original, calculations and this correction sheet. A separate sheet for response may be used.Resubmit corrected sets of plans.Meetings between the project applicant/designer and the plan reviewer shall be by appointment only. Please call (714) 647-5822 for an appointment.
5. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance (CHECKED BOXES REQUIRED ONLY):
☒Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process.
☐Public Works Agency approval (647-5039).
☐Fire Department approval on the corrected/final set of drawings (647-5839 or 647-5700).
☐Police Department approval on the corrected/final set of drawings (647-5840).
☐School District Approval; and a copy of the school fee worksheet, completed by the plan check engineer, shall be required by the School District to verify the scope of the work.
☐Proof of Worker's Compensation Insurance shall be required at the time of permit issuance.
☐Grading Permit. Application is made through the Building Safety Division (647-5800) and the plan review is by the Public Works Agency (647-5039).Comments have been provided on drawing and calculation hard copies in relation to all comments below. Applicant must pick up red marked sets from city prior to resubmittal and return marked up set with resubmittal.DrawingsSheet A0.0Code references shall be updated to current 2022 codes.Sheet S.0All code references shall be updated to current 2022 codes. (e.g. Nailing Schedule, Shearwall Schedule, etc…)Sheet S1Specify ridge member size at California framing or if 6x is continuous over post.Verify if 6x12 Ridge connection at existing house side is atop KP as noted or continuous post as shown in detail. If KP atop wall, provide detail specifying connection.PC #2: Provide bottom connection for full height post to existing foundation. Ensure existing foundation can support new ridge beam reaction along with existing roof trib bearing atop wall.Calculations specify to use 15” wide continuous foundation at single story. Revise to match or provide revised calculations.(End of Comment)