Loading...
HomeMy WebLinkAbout303152_1_Corrections.docxRESIDENTIAL PLAN CHECK COMMENTS Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org PLAN CHECK NO: 101115415 PROJECT ADDRESS: 2306 N Laird St Unit# 2 PLAN CHECK ENGINEER: Lee, WayneTEL:714 647-5848 EMAIL: wlee@santa-ana.orgFAX:714 647-5897 TYPE OF CONSTRUCTION: V B OCCUPANCY CLASSIFICATION(S): R-3, U PLAN CHECK DATES: REMARKS/RECHECK ITEMS: APPLICATION 6/12/2023 INITIAL REVIEW 7/26/2023 EXPIRATION 12/9/2023 RECHECKS: 1. PROJECT APPLICANT CONTACT PERSON: 2. Hoang Pham 3. TEL: (714)495-0056 FAX: VALUATION: $110,000.00 EMAIL: hdanpham@gmail.com FLOOD ZONE: X-0602320144J Note: Numbers in parenthesis (unless otherwise noted) refer to code sections of the 2022 California Residential Code (CRC); 2022 California Building Code (CBC); CMC = 2022 California Mechanical Code; CPC = 2022 California Plumbing Code; CEC = 2022 California Electrical Code; T = Table; ICC = International Code Council.All items noted on this plan check report must be addressed.Please indicate the sheet number and detail to the right of each correction, or note the number on the plans where the correction is made. A separate sheet for response may be used. This review does not include mechanical, plumbing or electrical work. Separate plans, applications, fees, plan checks, and permits are required for mechanical, plumbing, and electrical work. Call 647-5800 for information. The applicant shall obtain clearances/approvals for the following, prior to building permit issuance: -Planning Division approval on the corrected/final set of drawings (647-5804). Previously approved plans should be submitted to expedite the process. -Police Department approval on the corrected/final set of drawings (647-5840). -Public Works Agency approval (647-5039). - School District Compliance Certificate; and a copy of the building permit application, signed by the plan check engineer, shall be required by the School District to verify the scope of the work. PLAN CHECK COMMENTS ** All plan check comments are listed in this report. There is no additional comments marked on the drawings and no additional comments marked on the structural calculation. Sheet A1 Revise description of the scope of work to include construction of 24 square feet porch. Add 2022 CALGreen into the applicable codes. 1-hour fire rated construction for eave underside protection and exterior wall assembly are required on the south side of the ADU (Fire separation distance <5 feet). Provide and cross-reference assembly details into the site plan. Provide the following on address number: Show the location of the address number on the site plan. The address number shall be legible and placed in a position that is visible from the street or road fronting the property. The address number shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches in height with a stroke width of not less than 0.5 inches. Sheet A2 Provide 1-hour assembly details (protected from both side) separating between ADU and the house. Cross-reference assembly details into the floor plan. Provide a concrete landing on the exterior side of the bedroom #2 sliding door. (R311.3) Sheet A3 Section X-X. On the south exterior wall (FSD<5 feet), provide 5/8”-thick type “X” gypsum board on the interior side of the exterior wall for 1-hour fire protection. On the west elevation, please identify the header height and justify the bottom of the clear opening of the egress window not to exceed 44” maximum, measured from the floor surface. On plan, specify roof covering material with ICC number in the elevation and roof note #5. Cool roof is required per energy design (T24 sheet) with minimum solar reflectance: 0.75 and minimum emittance: 0.92. Specify CRRC number of the roof covering material on plan. Sheet A4. Callout attic vent locations, sizes and types on plans. Show specification of the vent to verify net vent free area is not less than 72 square inches per your attic ventilation calculation. Sheet T24. Revise orientation and size of the fenestration/glazing area to match the windows and glazed doors on the floor plan. STRUCTURAL Sheet S1 Add 2022 California Building Code into the applicable codes. The specified concrete strength in the structural calculation is 4,500 psi, but on the foundation notes, it shows 3,000 psi. Please clarify on plan to be consistent. Special inspection is required for concrete greater than 2,500 psi per CBC 1705.3 exception 2. Provide statement of special inspection on plan. Provide specification of the reinforcement steel. Provide schedule for footing and slab design as referenced on the foundation plan. Provide spread footing detail for installation of “PBS44”. Provide connection detail on plan showing connection of the rafters, ceilings and 4x10 beams (B2). END OF COMMENTS